{"product_id":"siemens-v23030-a1026-a104-axicom-4pdt-48vdc-signal-relay","title":"Siemens V23030-A1026-A104 Axicom 4PDT 48VDC Signal Relay","description":"\u003ch1 data-path-to-node=\"0\"\u003eSiemens V23030-A1026-A104 Axicom Signal Relay\u003c\/h1\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSiemens V23030-A1026-A104\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"1\" data-index-in-node=\"53\"\u003eV23030-A1026-A104\u003c\/b\u003e Signal Relay, operates as a dedicated hardware component for low-power signal switching and galvanic isolation within industrial electronic control platforms. Utilizing a 48 VDC non-latching coil operating at 17.8 mA, this 14-pin card-style relay actuates a 4PDT (4 Form C) gold-overlaid silver alloy contact set. It routes low-level electrical signals across four independent channels while withstanding maximum switching limits of 250 VAC \/ 250 VDC at 2 A nominal contact current.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003eV23030-A1026-A104\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eSiemens \/ TE Connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003eCzechia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003eStandard Axicom V23030 PCB package size\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003e0.85 W (48 VDC nominal coil drive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003eAxicom V23030 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,0,0\"\u003eRelay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,1,0\"\u003eSignal relay, general purpose\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,0,0\"\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,1,0\"\u003eThrough-hole PCB mount (14-pin)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,11,0,0\"\u003eContact Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,11,1,0\"\u003e4PDT (4 Form C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,12,0,0\"\u003eContact Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,12,1,0\"\u003eSilver alloy with gold overlay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,13,0,0\"\u003eRated Contact Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,13,1,0\"\u003e2 A nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,14,0,0\"\u003eMax Switching Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,14,1,0\"\u003e250 VAC \/ 250 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,15,0,0\"\u003eCoil Voltage \/ Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,15,1,0\"\u003e48 VDC \/ 17.8 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,16,0,0\"\u003eCoil Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,16,1,0\"\u003e2.7 kOhm (+-10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,17,0,0\"\u003eCoil Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,17,1,0\"\u003eNon-latching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,18,0,0\"\u003eOperate \/ Release Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,18,1,0\"\u003eOperate: 8 ms \/ Release: 2 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eFirmware Flash Compatibility\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe Siemens V23030-A1026-A104 functions as a purely electromechanical hardware layer component, operating completely transparently to controller firmware flash updates and system software revisions. Because signal routing occurs through direct metallic bridge actuation via gold-overlaid contacts, the relay maintains microsecond-level response times independent of host PLC or DCS processor scan execution cycles. Backplane communication interfaces and digital logic cards interact with the device through standard 48 VDC driver outputs without requiring specialized hardware drivers or peripheral bus configuration licenses.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eQ: How does the 4PDT contact configuration execute signal paths on the V23030-A1026-A104?\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eA: The 4PDT (4 Form C) contact setup provides four mechanically linked changeover circuits, enabling simultaneous switching of four independent differential signal loops using a single 48 VDC coil activation signal.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eQ: What physical limitations govern high-voltage and high-current power switching for this module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eA: Designed specifically for low-level signal conditioning, the gold-overlaid silver alloy contacts bear a nominal current rating of 2 A and a maximum switching threshold of 250 VAC \/ 250 VDC. Exceeding these thermal and dielectric thresholds will degrade contact plating and shorten mechanical operating life.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003eQ: What operational response timing does the non-latching 48 VDC coil deliver during state change?\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003eA: The coil features a 2.7 kOhm resistance profile, achieving full contact set pull-in (operate time) within 8 ms of voltage application and open drop-out (release time) within 2 ms upon power removal.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp data-path-to-node=\"15\"\u003ePosition the 14-pin through-hole relay onto the printed circuit board, ensuring pin alignment conforms strictly to standard DIP footprint dimensions. Solder all terminals using controlled wave-soldering or manual thermal profiles to prevent localized heat transfer to internal armature springs and contact assemblies. Maintain adequate clearance from neighboring high-power transformers or high-frequency inductors to eliminate electromagnetic interference on sensitive signal paths. Inspect terminal connections and test coil resistance prior to applying continuous 48 VDC potential.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43911881326691,"sku":"V23030-A1026-A104","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/143._de67f3db-5ec3-4f54-92f5-e448a6474433.jpg?v=1766539817","url":"https:\/\/www.autocontrolglobal.com\/products\/siemens-v23030-a1026-a104-axicom-4pdt-48vdc-signal-relay","provider":"AutoControl Global","version":"1.0","type":"link"}