{"product_id":"speedtronic-analog-input-card-is200tbaih1c-ge-mark-vi","title":"Speedtronic Analog Input Card | IS200TBAIH1C GE Mark VI","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200TBAIH1C serves as a critical Analog Input Terminal Board within the General Electric Mark VI Speedtronic control platform. This hardware facilitates the direct interface between field instruments—such as pressure transducers, temperature sensors, and flow meters—and the turbine control processor. By performing essential signal conditioning and noise filtration at the terminal level, the IS200TBAIH1C ensures the controller receives accurate, high-fidelity data for critical process loops. We supply this board in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, maintaining the strict electrical tolerances required for steam and gas turbine environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBAIH1C incorporates rugged circuitry designed to handle the electrical stresses of utility-scale power generation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200TBAIH1C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Mark VI Turbine Control System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePC Board \/ Analog Input Terminal Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCondition and route analog signals to the Mark VI processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports standard industrial analog inputs (4-20mA, voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated galvanic isolation for signal protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.00 lbs (0.45 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Mark VI Series footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200TBAIH1C utilizes high-grade filtering components to strip electromagnetic interference (EMI) from field wiring. This ensures that transient spikes from nearby heavy machinery do not corrupt the analog data used for turbine governing and safety trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Protection Barrier:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated isolation circuits decouple the sensitive control backplane from field-side electrical faults. This protection prevents surge-related damage from propagating to the primary control processor, significantly increasing system reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board features accessible test points and clear terminal labeling. These design elements allow maintenance teams to verify signal levels and diagnose sensor faults directly at the terminal strip without disrupting the system backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE engineered this board to operate in non-climate-controlled environments typical of localized turbine enclosures. It maintains calibration accuracy across a broad temperature spectrum, preventing signal drift in high-heat industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density terminal screw blocks accommodate various wire gauges. The mechanical layout provides ample space for cable routing, reducing the risk of short circuits during installation or routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IS200TBAIH1C require a specific termination block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200TBAIH1C acts as the terminal board itself. It connects via specialized ribbon cables or backplane connectors to the corresponding I\/O processor module in the Mark VI rack. Always verify that your processor module version (such as a VCMI or similar) matches the TBAIH hardware revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board hot-swappable during turbine operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the Mark VI system supports many hot-swappable components, you must follow specific GE safety protocols when replacing terminal boards. We recommend reviewing the system's redundancy configuration (Simplex vs. TMR) before attempting a live swap to avoid unintended signal interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the TBAIH and TBCIH models?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200TBAIH1C specifically handles\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(continuous signals like 4-20mA), whereas the TBCIH series manages\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eContact Inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(discrete ON\/OFF signals). These boards are not interchangeable and perform distinct functions within the control architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify that the board is a 100% Brand New unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery unit we supply arrives in factory-original anti-static packaging with intact manufacturer seals. As a technical provider, we ensure the hardware has never been energized or used in a field environment, guaranteeing maximum MTBF (Mean Time Between Failure).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44098869756003,"sku":"IS200TBCIH1C","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/367._29905365-4ef6-4e04-9d17-f45795066366.jpg?v=1775205475","url":"https:\/\/www.autocontrolglobal.com\/products\/speedtronic-analog-input-card-is200tbaih1c-ge-mark-vi","provider":"AutoControl Global","version":"1.0","type":"link"}