{"product_id":"speedtronic-mark-v-digital-i-o-module-ge-ds200tcdah1bg","title":"Speedtronic Mark V Digital I\/O Module | GE DS200TCDAH1BG","description":"\u003ch2\u003eGE DS200TCDAH1BG Mark V Series Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital input and output processing in Mark V Control System networks, the \u003cstrong\u003eGE DS200TCDAH1BG\u003c\/strong\u003e (\u003cstrong\u003eGE DS200TCDA\u003c\/strong\u003e Digital I\/O Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCDAH1BG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 lb (454 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e168 x 150 x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard rack slot allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Routing\u003c\/td\u003e\n\u003ctd\u003eSensors, switches, relays, and solenoids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eIntegrated self-test routines and fault indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V rack structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Coupling and I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCDAH1BG manages bidirectional digital data flows by routing discrete field contact variables into the core processing environment. The board incorporates dedicated communication layers configured for Modbus TCP\/IP industrial networks, ensuring low-latency data transmission across distributed control frameworks. This digital interface design provides specific firmware flash compatibility to synchronize discrete logic states directly with upstream turbine control processors, maintaining system deterministic network execution while mitigating propagation delay across high-density I\/O configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the DS200TCDAH1BG field-replaceable during turbine operation?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must execute module replacement during scheduled system downtime. Controlled hot-swap replacement depends entirely on active redundant rack topologies and local engineering safety interlocks.\u003c\/p\u003e\n\u003cp\u003eQ: What communication options does this board support?\u003c\/p\u003e\n\u003cp\u003eA: The module executes digital communication through native Modbus TCP\/IP protocol support, enabling standard Ethernet integration with adjacent plant networks.\u003c\/p\u003e\n\u003cp\u003eQ: Does the board handle both digital inputs and outputs simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture routes incoming 24 VDC dry contact inputs while driving independent output control channels for external solenoids and interposing relays.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion\u003c\/strong\u003e: Slide the module into the designated slot of the Mark V chassis framework. Ensure complete alignment with the rear backplane connectors. Apply steady force to engage the pins fully, then tighten all faceplate screws to establish solid chassis ground continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Termination and Shielding\u003c\/strong\u003e: Connect 24 VDC input and output field loops to the correct terminal allocations. Separate all discrete I\/O wiring from high-voltage AC cables inside the wireways to avoid capacitive noise coupling. Terminate the overall cable shields at the dedicated cabinet ground bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal and Inspection Routines\u003c\/strong\u003e: Verify that cabinet ventilation systems maintain ambient airflow paths within the rated -40 to +70 deg C parameters. Perform routine visual inspections of the printed circuit board components to ensure no particulate accumulation disrupts physical trace insulation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43870259413091,"sku":"DS200TCDAH1BG","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/324_dceda4fe-9605-48a4-84a7-eb2aa8b66969.jpg?v=1764811925","url":"https:\/\/www.autocontrolglobal.com\/products\/speedtronic-mark-v-digital-i-o-module-ge-ds200tcdah1bg","provider":"AutoControl Global","version":"1.0","type":"link"}