{"product_id":"speedtronic-simplex-terminal-board-ge-is200staih2abb-mark-vie","title":"Speedtronic Simplex Terminal Board GE IS200STAIH2ABB Mark VIe","description":"\u003ch2\u003eGE IS200STAIH2ABB Mark VIe Simplex Analog Input Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal acquisition and transducer loop interface in Mark VIe control systems, the \u003cstrong\u003eGE IS200STAIH2ABB\u003c\/strong\u003e (\u003cstrong\u003eIS200STAI\u003c\/strong\u003e Simplex Analog Input Terminal Board) provides direct physical and electrical execution. The hardware accommodates two-wire, three-wire, four-wire, and externally powered transmitters, routing dynamic signal loops through active filtering circuits. Featuring 1500 VDC channel-to-bus galvanic isolation, the terminal card conditions field transmitter inputs and manages jumper-configurable analog output channels before transmitting digitized process data across the system backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STAIH2ABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e233 mm x 167 mm (Standard 6U VME Form Factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC via Backplane Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ Mark VIe Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e10 Analog Inputs \/ 2 Analog Outputs (Up to 24 Channel Capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signal Inputs\u003c\/td\u003e\n\u003ctd\u003eCurrent (4-20 mA), Voltage (0-10 VDC), RTD Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eTwo Jumper-Configurable Outputs (0-20 mA, one up to 0-200 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VDC Channel-to-Bus Galvanic Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen-Circuit and Over-Range Line Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals with Wire Guards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200STAIH2ABB\u003c\/strong\u003e exchanges real-time process data with system I\/O packs across the backplane bus, maintaining high communication velocity to prevent scan delays in closed-loop control routines. Internal firmware flash compatibility ensures seamless handshaking between onboard signal conditioning circuitry and central processing algorithms. The hardware handles high-density transmitter scaling without dropping scan frames, preserving deterministic data throughput and system timing across dynamic control cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does jumper selection alter the current limits on the analog output channels?\u003c\/p\u003e\n\u003cp\u003eA: Engineers adjust onboard hardware jumpers to set output ranges between standard 0-20 mA limits or configure the designated high-current drive output up to 0-200 mA.\u003c\/p\u003e\n\u003cp\u003eQ: What happens when an analog input transmitter experiences a wire break or open loop?\u003c\/p\u003e\n\u003cp\u003eA: Integrated diagnostic circuits detect the open-circuit condition, flag the fault status to the controller via the backplane bus, and hold the channel in a safe predefined state.\u003c\/p\u003e\n\u003cp\u003eQ: Can two-wire, three-wire, and four-wire field transmitters connect to the same terminal board?\u003c\/p\u003e\n\u003cp\u003eA: Yes, terminal block power distribution nodes accommodate two-wire, three-wire, four-wire, and externally powered loop configurations simultaneously across individual channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eExecute the following steps during physical mounting and field wiring setup:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Board Securing\u003c\/strong\u003e: Mount the 6U card assembly securely into the cabinet chassis rail, tightening frame hardware to establish a solid chassis ground reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conductor Hookup\u003c\/strong\u003e: Strip field wire ends and insert them into the designated screw terminal points, ensuring wire guards prevent strand damage during tightening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Cable Termination\u003c\/strong\u003e: Connect individual cable drain wires directly to the cabinet ground bar to maintain single-point earthing and suppress high-frequency interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration Check\u003c\/strong\u003e: Set output channel range jumpers to the required 0-20 mA or 0-200 mA operating modes prior to connecting actuator drive circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Connector Inspection\u003c\/strong\u003e: Inspect multi-pin ribbon interface cables for pin alignment before locking side latches to ensure reliable backplane bus connection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44451804217443,"sku":"IS200STAIH2ABB","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/458_04fc358b-ca56-45c2-beab-4e88f863d852.jpg?v=1786009430","url":"https:\/\/www.autocontrolglobal.com\/products\/speedtronic-simplex-terminal-board-ge-is200staih2abb-mark-vie","provider":"AutoControl Global","version":"1.0","type":"link"}