{"product_id":"sptps13-abb-symphony-plus-speed-detection-module","title":"SPTPS13 ABB Symphony Plus Speed Detection Module","description":"\u003ch2\u003eABB SPTPS13 Symphony Plus Harmony Rack Turbine Protection Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eSPTPS13\u003c\/strong\u003e is a multi-function turbine protection and speed detection module for the Symphony Plus Harmony Rack (HR Series) platform. It executes high-speed speed monitoring, overspeed protection, and emergency trip functions for steam and gas turbines. Operating across three selectable modes (TPS, FCS, and TSA), the module consolidates the capabilities of legacy SPTPS02, SPFCS01, and SPTSA01 modules into a single hardware assembly, featuring triple-redundant speed inputs with 2-out-of-3 voting logic and online testing.\u003c\/p\u003e\n\u003cp\u003eABB SPTPS13 turbine protection module. 来源：Evaflux\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSPTPS13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eHarmony Rack (HR Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTurbine Protection and Speed Detection Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eTPS (Turbine Protection System), FCS (Fault Control System), TSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLegacy Replacement\u003c\/td\u003e\n\u003ctd\u003eConsolidates SPTPS02, SPFCS01, and SPTSA01 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Redundancy\u003c\/td\u003e\n\u003ctd\u003eTriple-redundant speed inputs with 2-of-3 voting logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Probe Input Frequency\u003c\/td\u003e\n\u003ctd\u003e0.5 to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Probe Input Voltage\u003c\/td\u003e\n\u003ctd\u003e0.05 to 120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs \/ Outputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs \/ Outputs\u003c\/td\u003e\n\u003ctd\u003e24 V DC (mode dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverspeed Protection Threshold\u003c\/td\u003e\n\u003ctd\u003eActivates at 110% of rated turbine speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Communication\u003c\/td\u003e\n\u003ctd\u003e8-bit parallel bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Termination Units\u003c\/td\u003e\n\u003ctd\u003eTPSTU02, TPTU02, NTDI01, NTDI02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmony Function Codes\u003c\/td\u003e\n\u003ctd\u003eFC 145, FC 79, FC 83, FC 84 (TPS); FC 145 (FCS); FC 103 (TSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltages\u003c\/td\u003e\n\u003ctd\u003e+15 V DC (±5% at 320 mA), +5 V DC (±5% at 100 mA), +24 V DC (±10% at 75 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.8 W (+15 V rail), 0.5 W (+5 V rail), 1.8 W (+24 V rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot Symphony Plus rack module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90% up to 55 deg C; 5% to 40% up to 70 deg C (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpeed Sensing and Overspeed Trip Logic\u003c\/h3\u003e\n\u003cp\u003eThe SPTPS13 processes speed signal inputs from electromagnetic or proximity speed probes operating between 0.5 and 20 kHz over an input voltage envelope of 0.05 to 120 V AC. In Turbine Protection System (TPS) mode, the module evaluates triple-redundant inputs using 2-out-of-3 voting logic to verify speed conditions before initiating safety trips.\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003eVerification:\u003c\/i\u003e Confirm that the speed probe signal amplitude remains within 0.05 to 120 V AC across the full 0.5 to 20 kHz operating frequency band.\u003c\/p\u003e\n\u003cp\u003eOverspeed trip functions activate at 110% of the rated turbine speed to safeguard rotating machinery. The module supports online testing routines to verify trip solenoid logic and diagnostic integrity during continuous plant operations.\u003c\/p\u003e\n\u003ch3\u003eMulti-Mode Operating Architecture and Rack Integration\u003c\/h3\u003e\n\u003cp\u003eOperating modes—TPS, FCS, or TSA—are selected using dedicated adapter boards inserted on the module. Harmony function codes FC 145, 79, 83, and 84 govern TPS operation, FC 145 drives FCS mode, and FC 103 manages TSA configurations.\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003eVerification:\u003c\/i\u003e Ensure the appropriate adapter board and function code parameters match the target legacy module (SPTPS02, SPFCS01, or SPTSA01) being replaced.\u003c\/p\u003e\n\u003cp\u003eThe single-slot module mounts into standard Symphony Plus Harmony Rack chassis, interfacing with backplane power rails (+15 V DC, +5 V DC, and +24 V DC) and connecting to field termination units including TPSTU02, TPTU02, NTDI01, and NTDI02.\u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which legacy Harmony Rack modules can be replaced by the SPTPS13? A: The SPTPS13 consolidates and directly replaces the earlier SPTPS02, SPFCS01, and SPTSA01 turbine protection modules.\u003c\/p\u003e\n\u003cp\u003eQ: How is the specific operating mode configured on the SPTPS13 module? A: Operating modes (TPS, FCS, or TSA) are selected by installing dedicated adapter boards onto the module assembly.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply rails are required from the backplane bus? A: The module draws power across three backplane rails: +15 V DC at 320 mA, +5 V DC at 100 mA, and +24 V DC at 75 mA.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43780249747555,"sku":"SPTPS13","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/961.jpg?v=1794204638","url":"https:\/\/www.autocontrolglobal.com\/products\/sptps13-abb-symphony-plus-speed-detection-module","provider":"AutoControl Global","version":"1.0","type":"link"}