{"product_id":"stbnip2311-schneider-modicon-stb-ethernet-interface-module","title":"STBNIP2311 Schneider Modicon STB Ethernet Interface Module","description":"\u003ch2\u003eSchneider Electric STBNIP2311 Modicon STB Ethernet Network Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSTBNIP2311\u003c\/strong\u003e is a standard Ethernet Network Interface Module (NIM) for the Modicon STB distributed I\/O system. Mounted at the head of an STB island, it links up to 32 addressable I\/O modules to industrial controllers over Modbus TCP\/IP. Dual 10\/100 Mbps RJ45 ports, an integrated 5.25 VDC logic bus supply, and an embedded web server handle island communication, bus power, and diagnostics.\u003c\/p\u003e\n\u003ch3\u003eEthernet Connectivity and Island Topology\u003c\/h3\u003e\n\u003cp\u003eTwo RJ45 ports supporting 10BASE-T and 100BASE-TX (IEEE 802.3) in half- or full-duplex mode allow daisy-chain Ethernet connections with segment lengths up to 100 m. Network setup supports BootP\/DHCP IP assignment, while SNMP and the built-in web server provide remote status and diagnostic visibility.\u003c\/p\u003e\n\u003cp\u003eWithin a Modicon STB island, the module coordinates 0 to 32 addressable I\/O modules across 1 primary segment and up to 6 extension segments. Front-panel LED indicators (ACT, RUN, ERR, MS, NS, PWR, and TEST) show local link activity, module health, and power states.\u003c\/p\u003e\n\u003ch3\u003ePower Distribution and Mechanical Limits\u003c\/h3\u003e\n\u003cp\u003eDrawing 550 mA from a 24 VDC supply (19.2 to 30 VDC operating range), the module provides 5.25 VDC at 1.2 A nominal current to the STB logic bus. Total logic bus demand from connected I\/O modules must stay within the 1.2 A output rating, or auxiliary bus power distribution modules are needed on larger islands.\u003c\/p\u003e\n\u003cp\u003eThe IP20 enclosure mounts onto a Modicon STB mounting base and measures 40.5 mm x 130 mm x 70 mm at 0.145 kg. It operates from 0 to 60 deg C and stores from -40 to 85 deg C at up to 95 % non-condensing relative humidity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSTBNIP2311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon STB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Network Interface Module (Standard NIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 (10BASE-T \/ 100BASE-TX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps (half \/ full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Ethernet Segment Length\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Services\u003c\/td\u003e\n\u003ctd\u003eSNMP, BootP\/DHCP, embedded web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2 to 30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e550 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Bus Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5.25 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Logic Bus Output Current\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressable I\/O Modules\u003c\/td\u003e\n\u003ctd\u003e0 to 32 modules per island\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsland Segments\u003c\/td\u003e\n\u003ctd\u003e1 primary + up to 6 extensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eACT, RUN, ERR, MS, NS, PWR, TEST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eModicon STB mounting base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e40.5 mm x 130 mm x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.145 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O modules and segments can one Schneider Electric STBNIP2311 manage? A: It manages 0 to 32 addressable I\/O modules across 1 primary segment and up to 6 extension segments per Modicon STB island.\u003c\/p\u003e\n\u003cp\u003eQ: Does the STBNIP2311 supply logic bus power to attached I\/O modules? A: Yes. Powered by 24 VDC (19.2 to 30 VDC), it outputs 5.25 VDC at 1.2 A nominal current to the internal STB logic bus.\u003c\/p\u003e\n\u003cp\u003eQ: Why does the STBNIP2311 have two RJ45 Ethernet ports? A: Dual 10\/100 Mbps RJ45 ports support daisy-chain Ethernet wiring between adjacent network nodes up to 100 m per segment without needing an external switch at every island.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67957009088611,"sku":"STBNIP2311","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/326._17e0323f-f0f8-4f60-94cf-a05b851633cd.jpg?v=1795059163","url":"https:\/\/www.autocontrolglobal.com\/products\/stbnip2311-schneider-modicon-stb-ethernet-interface-module","provider":"AutoControl Global","version":"1.0","type":"link"}