{"product_id":"tc-rpfm01-honeywell-experion-controlnet-fiber-optic-repeater","title":"TC-RPFM01 Honeywell Experion ControlNet Fiber Optic Repeater","description":"\u003ch2\u003eHoneywell TC-RPFM01 Experion ControlNet Fiber Optic Repeater Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-RPFM01\u003c\/strong\u003e is a ControlNet fiber optic repeater module engineered for Honeywell Experion systems, including Experion PKS and Experion LS control architectures. Installed in a repeater rack assembly alongside a ControlNet repeater adapter, it converts electrical coaxial ControlNet signals into optical signals to extend network segments beyond copper cable distance limits while preventing electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eOptical Transmission Capabilities and Distance\u003c\/h3\u003e\n\u003cp\u003eThe module operates at the standard ControlNet communication rate of 5 Mbps. Utilizing optical fiber media, it supports network signal extension up to 3 km (9,842 ft) with an optical power budget of 13.3 dB at a 1300 nm optical wavelength, maintaining signal integrity and galvanic isolation between connected control zones.\u003c\/p\u003e\n\u003ch3\u003eHardware Interface and Operating Specifications\u003c\/h3\u003e\n\u003cp\u003eThe unit interfaces with the local repeater adapter via a vendor-specific 30-pin TTL bus connector, receiving internal operating power directly through the adapter module. Designed for industrial enclosures, the module operates across a temperature range of -20 deg C to +70 deg C and features shock resistance rated at 15 g peak (11 ms duration) alongside vibration resistance per IEC 68-2-6 standards.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-RPFM01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControlNet Fiber Optic Repeater Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS, Experion LS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd\u003e5 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 3 km (9,842 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Wavelength\u003c\/td\u003e\n\u003ctd\u003e1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Power Budget\u003c\/td\u003e\n\u003ctd\u003e13.3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Cable \u0026amp; Connector\u003c\/td\u003e\n\u003ctd\u003e62.5\/125 um fiber, ST connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bus Interface\u003c\/td\u003e\n\u003ctd\u003eVendor-specific 30-pin TTL bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eSupplied through Repeater Adapter module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eTTL bus \/ ControlNet isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock \u0026amp; Vibration Resistance\u003c\/td\u003e\n\u003ctd\u003eShock: 15 g peak (11 ms); Vibration: 2 g, 10–500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e94 mm × 94 mm × 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.147 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCSA approved for hazardous environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What transmission distance can be achieved using the Honeywell TC-RPFM01 module?\u003c\/p\u003e\n\u003cp\u003eA: The module supports optical ControlNet signal transmission up to 3 km (9,842 ft) using a 1300 nm wavelength with a 13.3 dB optical power budget.\u003c\/p\u003e\n\u003cp\u003eQ: How is power supplied to the TC-RPFM01 fiber repeater module?\u003c\/p\u003e\n\u003cp\u003eA: Internal operating power is drawn directly from the backplane via the connected ControlNet repeater adapter module through its 30-pin TTL bus interface.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43794931908707,"sku":"TC-RPFM01","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/500_fb24d050-6ef8-4413-bb6e-6109785f8a6c.jpg?v=1761552939","url":"https:\/\/www.autocontrolglobal.com\/products\/tc-rpfm01-honeywell-experion-controlnet-fiber-optic-repeater","provider":"AutoControl Global","version":"1.0","type":"link"}