Temperature Input Modules | Honeywell MC-TSIM12 51303932-476
Temperature Input Modules | Honeywell MC-TSIM12 51303932-476
Temperature Input Modules | Honeywell MC-TSIM12 51303932-476
/ 3

Temperature Input Modules | Honeywell MC-TSIM12 51303932-476

  • Manufacturer: HONEYWELL

  • Part Number: MC-TSIM12 51303932-476

  • Condition:New with Original Package

  • Product Type: Temperature Input Modules

  • Country of Origin: Sweden

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Honeywell 51303932-476 MC-TSIM12 Temperature Input Card

The Honeywell 51303932-476, also cataloged as the MC-TSIM12 Temperature Input Module, serves as the primary MC-TSIM12 Product Type utilized to execute precise temperature acquisition across Experion PKS Series C platforms. The assembly interfaces with thermocouple and RTD field sensors, converting analog millivolt and resistance signals into 16-bit digital values while maintaining galvanic isolation between channels.

Hardware Specifications

Parameter Specification
Model MC-TSIM12 (Part Number: 51303932-476)
Brand Honeywell
Origin Factory standard
Weight 0.5 kg
Dimensions 267 x 178 x 51 mm
Operating Temp -20 to +55 deg C
Power Consumption 3.5 W
Number of Channels 16 isolated input channels
Temperature Range -200 to +1800 deg C (sensor dependent)
Accuracy +/-0.1% of span or better
Resolution 16-bit A/D conversion
Cold Junction Compensation Built-in automatic CJC
Isolation Strength 500 Vrms channel-to-channel and channel-to-system
Update Rate <= 100 ms per channel
Operating Voltage 24 VDC supplied via backplane

Process Control & Cold Junction Compensation

The hardware architecture incorporates automatic cold junction compensation (CJC) directly on the terminal assembly to ensure measurement accuracy for thermocouple inputs. Channel-to-channel isolation rated at 500 Vrms prevents ground loops and electrical cross-talk from degrading low-level sensor signals in high-noise process environments. The 16-bit analog-to-digital converters process inputs within a 100 ms update window, while internal diagnostic algorithms continuously monitor for open sensors and field wiring faults.

Frequently Asked Questions

Q: What specific sensor types can the input channels interface with?

A: The module supports a standardized list of temperature elements, including J, K, T, E, N, R, S, and B type thermocouples, alongside Pt100, Pt1000, Ni100, and Cu10 RTD configurations.

Q: How does the module handle a broken sensor or severed field lead wire?

A: The card implements on-board sensor diagnostics that instantly flag open circuits and sensor faults, tripping dedicated diagnostic bits and illuminating local status LEDs.

Q: Can this card be interchanged with other Honeywell DCS architectures?

A: The physical and electrical design maintains compatibility across Experion PKS Series C, TPS, and TDC 3000 systems.

Field Installation Guidelines

  • Isolate all system backplane power prior to inserting or extracting the temperature card to protect the 16-bit A/D circuitry from inductive transients.
  • Run all low-voltage thermocouple and RTD wiring in dedicated, shielded cable trays separated from high-current AC motor leads.
  • Terminate the overall cable shields exclusively at the designated instrument ground rail to minimize electromagnetic noise injection.
  • Verify that the CJC sensor blocks are seated correctly on the terminal block assembly to prevent tracking errors during environmental temperature variations.
You may also like