{"product_id":"triconex-p13382-tricon-safety-main-processor-module","title":"Triconex P13382 Tricon Safety Main Processor Module","description":"\u003ch2\u003eTriconex P13382 Main Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for executing safety logic and coordinating system communications in Tricon Safety Instrumented Systems, the \u003cstrong\u003eTriconex P13382\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePI3382\u003c\/strong\u003e Main Processor Module, provides direct physical and electrical execution of critical protection algorithms. The module manages input\/output synchronization and continuous self-test diagnostics directly across the internal system backplane without requiring external supervisory interventions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTriconex P13382 \/ PI3382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Chassis Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Tricon Slot Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMain Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eTricon Safety Instrumented System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Architecture\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundancy (TMR) 2oo3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Execution Cycle\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003eHigh-capacity non-volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eContinuous self-test and fault supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL3 compliant (IEC 61508, TUV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFunctional Safety \u0026amp; Redundancy Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTriconex P13382\u003c\/strong\u003e utilizes a Triple Modular Redundant (TMR) architecture to achieve certified SIL3 operational compliance. Internal processing runs across three isolated processing channels that continuously execute system logic in parallel. Hardware-based 2oo3 (two-out-of-three) voting circuitry compares all execution outputs before driving backplane signals to destination I\/O modules. Galvanic isolation across communication paths prevents physical faults on one leg from propagating to redundant channels, ensuring fail-safe state execution and uninterrupted system availability during single-component hardware anomalies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the Triconex P13382 module be replaced while the safety system remains online?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports online replacement within approved redundant rack configurations. Technicians can insert the replacement processor into the designated slot, allowing the active redundant processors to synchronize safety logic state data automatically across the backplane without disrupting process operations.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit handle internal memory integrity during system power disruptions?\u003c\/p\u003e\n\u003cp\u003eA: Logic programs and configuration data reside within high-capacity non-volatile memory. Upon detection of power degradation, internal supervisors commit active states to non-volatile storage, preventing software corruption and ensuring deterministic reboot sequence execution when backplane power restores.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation requires strict adherence to physical and electrical isolation standards to preserve certified safety integrity:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInsert the module firmly into its designated chassis slot until the top and bottom retaining levers engage the backplane connectors fully.\u003c\/li\u003e\n\u003cli\u003eTighten the top and bottom panel mounting screws to secure the module against vibration and to maintain effective chassis grounding.\u003c\/li\u003e\n\u003cli\u003eEnsure the cabinet ambient temperature remains within the specified -40 deg C to +70 deg C envelope by verifying proper airflow through enclosure cooling vents.\u003c\/li\u003e\n\u003cli\u003eVerify that all cabinet drain wires and cable shields terminate directly to the central instrumentation ground bus using low-impedance grounding straps.\u003c\/li\u003e\n\u003cli\u003eDo not leave processor slots uncovered; install proper chassis slot covers over unused slots to maintain correct thermal convection profiles.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43927744118883,"sku":"PI3382","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/102_6e33a94a-5528-4af3-a30d-0eb6b0619e23.jpg?v=1767144287","url":"https:\/\/www.autocontrolglobal.com\/products\/triconex-p13382-tricon-safety-main-processor-module","provider":"AutoControl Global","version":"1.0","type":"link"}