TSXAEG4111 Schneider Modicon Analog Input Module | New & Original Stock
TSXAEG4111 Schneider Modicon Analog Input Module | New & Original Stock
TSXAEG4111 Schneider Modicon Analog Input Module | New & Original Stock
/ 3

TSXAEG4111 Schneider Modicon Analog Input Module | New & Original Stock

  • Manufacturer: Schneider

  • Part Number: TSXAEG4111

  • Condition:New with Original Package

  • Product Type: Analog Input Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Schneider TSXAEG4111 Modicon TSX Series 7 Analog Input Module

Configured for converting field analog signals into precise digital data for PLC processing in legacy architectures, the Schneider TSXAEG4111 (TSXAEG4111 Analog Input Module) provides direct physical/electrical execution across eight independent instrumentation channels.

Hardware Specifications

Parameter Specification
Model TSXAEG4111
Brand Schneider Electric / Telemecanique
Origin France
Weight 200 g
Dimensions 110 mm x 30 mm x 22 mm
Operating Temp 0 to 60 deg C
Storage Temp -40 to 85 deg C
Relative Humidity 5% to 95% non-condensing
Power Consumption 1.5 W
Power Supply 5 VDC via PLC backplane bus
Number of Channels 8 analog inputs
Supported Input Types Voltage and current
Input Ranges Plus/minus 10 V, plus/minus 5 V, 1 to 5 V, 4 to 20 mA, plus/minus 20 mA
Resolution 16-bit analog-to-digital conversion
Accuracy Plus/minus 0.1% of full scale
Isolation Channel-to-channel and channel-to-ground isolation
Communication Interface Modbus RTU protocol layer
Certifications CE, UL, CSA

Industrial Control & I/O Density Scaling

The internal architecture of the TSXAEG4111 relies on high-resolution 16-bit analog-to-digital converters mapped to rigid backplane bus communication velocity constraints. When scaling I/O density within Telemecanique Modicon TSX Series 7 rack assemblies, the concurrent monitoring of multiple voltage and current signals requires strict enforcement of channel-to-channel isolation parameters to prevent electrical cross-talk. To preserve the plus/minus 0.1% accuracy threshold under continuous processing cycles, firmware flash compatibility must be verified across the master CPU platform, ensuring deterministic synchronization windows between the 5 VDC logic bus and the Modbus RTU interface layers.

Frequently Asked Questions

Q: How is the input range configuration determined for individual channels on the TSXAEG4111?

A: Channel parameters, including voltage and current configurations (such as 4-20 mA or plus/minus 10 V), must be assigned programmatically through the host configuration software or set via physical jumpers on the module circuit board prior to slot insertion.

Q: What are the continuous electrical limitations of the internal backplane power distribution?

A: The module draws exactly 1.5 W from the 5 VDC backplane power rail supplied by the rack power module. The total current budget of the specific Modicon TSX Series 7 segment must be calculated to prevent voltage dropouts across adjacent modules.

Q: How does channel-to-channel isolation protect the 16-bit analog-to-digital conversion circuitry?

A: The integrated galvanic isolation blocks high common-mode voltages and electrical noise from propagating between input loops. This protects the internal multiplexer and resistor arrays from damage if an individual field sensor experiences an electrical fault or ground loop spike.

Field Installation Guidelines

  • Chassis Alignment and Insertion: Insert the module into the designated slot of the Modicon TSX Series 7 backplane rack. Apply even pressure until the edge connector is seated completely within the backplane socket, then lock the mechanical retention latch to ensure continuous grounding.
  • Instrumentation Cable Shielding: Connect all 4-20 mA or voltage loops using twisted-pair instrumentation cables with overall copper braided shielding. Ground the cable shield at a single point on the enclosure earth bus bar to mitigate external high-frequency electrical noise.
  • Convection Cooling and Airflow: Maintain proper vertical spacing between adjacent wire ducts and the rack assembly to ensure unhindered thermal convection. Operating the module outside the 0 to 60 deg C window without air movement will accelerate thermal drift and compromise measurement accuracy.