{"product_id":"tsxaeg4111-schneider-modicon-analog-input-module-new-original-stock","title":"TSXAEG4111 Schneider Modicon Analog Input Module | New \u0026 Original Stock","description":"\u003ch2\u003eSchneider TSXAEG4111 Modicon TSX Series 7 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for converting field analog signals into precise digital data for PLC processing in legacy architectures, the \u003cstrong\u003eSchneider TSXAEG4111\u003c\/strong\u003e (\u003cstrong\u003eTSXAEG4111\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution across eight independent instrumentation channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXAEG4111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \/ Telemecanique\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 30 mm x 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC via PLC backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Input Types\u003c\/td\u003e\n\u003ctd\u003eVoltage and current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003ePlus\/minus 10 V, plus\/minus 5 V, 1 to 5 V, 4 to 20 mA, plus\/minus 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003ePlus\/minus 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eModbus RTU protocol layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture of the TSXAEG4111 relies on high-resolution 16-bit analog-to-digital converters mapped to rigid backplane bus communication velocity constraints. When scaling I\/O density within Telemecanique Modicon TSX Series 7 rack assemblies, the concurrent monitoring of multiple voltage and current signals requires strict enforcement of channel-to-channel isolation parameters to prevent electrical cross-talk. To preserve the plus\/minus 0.1% accuracy threshold under continuous processing cycles, firmware flash compatibility must be verified across the master CPU platform, ensuring deterministic synchronization windows between the 5 VDC logic bus and the Modbus RTU interface layers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the input range configuration determined for individual channels on the TSXAEG4111?\u003c\/p\u003e\n\u003cp\u003eA: Channel parameters, including voltage and current configurations (such as 4-20 mA or plus\/minus 10 V), must be assigned programmatically through the host configuration software or set via physical jumpers on the module circuit board prior to slot insertion.\u003c\/p\u003e\n\u003cp\u003eQ: What are the continuous electrical limitations of the internal backplane power distribution?\u003c\/p\u003e\n\u003cp\u003eA: The module draws exactly 1.5 W from the 5 VDC backplane power rail supplied by the rack power module. The total current budget of the specific Modicon TSX Series 7 segment must be calculated to prevent voltage dropouts across adjacent modules.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation protect the 16-bit analog-to-digital conversion circuitry?\u003c\/p\u003e\n\u003cp\u003eA: The integrated galvanic isolation blocks high common-mode voltages and electrical noise from propagating between input loops. This protects the internal multiplexer and resistor arrays from damage if an individual field sensor experiences an electrical fault or ground loop spike.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment and Insertion:\u003c\/strong\u003e Insert the module into the designated slot of the Modicon TSX Series 7 backplane rack. Apply even pressure until the edge connector is seated completely within the backplane socket, then lock the mechanical retention latch to ensure continuous grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrumentation Cable Shielding:\u003c\/strong\u003e Connect all 4-20 mA or voltage loops using twisted-pair instrumentation cables with overall copper braided shielding. Ground the cable shield at a single point on the enclosure earth bus bar to mitigate external high-frequency electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Cooling and Airflow:\u003c\/strong\u003e Maintain proper vertical spacing between adjacent wire ducts and the rack assembly to ensure unhindered thermal convection. Operating the module outside the 0 to 60 deg C window without air movement will accelerate thermal drift and compromise measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43903096455267,"sku":"TSXAEG4111","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/179_df5491ad-147b-46b4-a4f4-a3305ca2b481.jpg?v=1766367020","url":"https:\/\/www.autocontrolglobal.com\/products\/tsxaeg4111-schneider-modicon-analog-input-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}