{"product_id":"tsxaez801-schneider-modicon-tsx-micro-input-module-new-original-stock","title":"TSXAEZ801 Schneider Modicon TSX Micro Input Module | New Original Stock","description":"\u003ch2\u003eSchneider TSXAEZ801 Modicon TSX Micro Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for acquiring voltage signals from field devices and converting them into digital values for PLC processing, the \u003cstrong\u003eSchneider TSXAEZ801\u003c\/strong\u003e (\u003cstrong\u003eTSXAEZ801\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution for eight independent instrument channels within Modicon TSX Micro Automation Platform racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXAEZ801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 cm x 18.0 cm x 26.0 cm (Package Dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.068% per 10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 mA current consumption from the backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Type\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion Resolution\u003c\/td\u003e\n\u003ctd\u003e11 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Period\u003c\/td\u003e\n\u003ctd\u003e32 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e2.2 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V AC between inputs and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eLegacy product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe internal circuitry of the TSXAEZ801 executes analog-to-digital data updates on a fixed 32 ms acquisition period. When optimizing I\/O density scaling inside compact Modicon TSX Micro racks, processing these eight voltage lines requires strict attention to backplane bus communication velocity limits to prevent data collisions. Maintaining correct firmware flash compatibility across the host processor ensures that the 11-bit plus sign resolution registers update concurrently without dropping packets, stabilizing measurement repeatability across all 0 to 10 V signal loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 2.2 Ohm input impedance parameter affect sensor matching?\u003c\/p\u003e\n\u003cp\u003eA: The 2.2 Ohm input impedance profile is exceptionally low for a 0 to 10 V voltage module. Connected field transmitters must possess a low source impedance and high driving current capability to deliver stable signals into this channel structure without voltage drop or signal distortion.\u003c\/p\u003e\n\u003cp\u003eQ: What are the isolation barriers between the input channels and the internal PLC logic?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates a galvanic isolation layer rated for up to 1000 V AC. This boundary protects the internal 60 mA logic bus from high-voltage transient noise and common-mode spikes that may develop on the field instrumentation ground line.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping permitted for this module within the TSX Micro chassis?\u003c\/p\u003e\n\u003cp\u003eA: No. Modicon TSX Micro hardware requires complete power isolation before extracting or executing the installation of any module component. Live insertion threatens the system bus data frames and can cause permanent component failure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Engagement and Mechanical Locking:\u003c\/strong\u003e Slide the module completely into the assigned slot on the TSX Micro chassis. Verify that the rear connectors seat securely into the backplane, and hand-tighten any standard retention fasteners to establish solid grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrumentation Voltage Cable Shielding:\u003c\/strong\u003e Run all 0 to 10 V voltage lines inside dedicated low-voltage wire trays separated from heavy motor leads. Connect twisted-pair instrumentation wires with an overall braided shield, grounding the shield layer exclusively at the master enclosure ground rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Mitigation Layout:\u003c\/strong\u003e Because temperature variations cause an accuracy drift of 0.068% per 10 deg C, maintain adequate convective airflow patterns around the module rack to prevent localized heat accumulation within the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43903098847331,"sku":"TSXAEZ801","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/182_22239913-bc60-44cd-a544-f9e09e7d3f6b.jpg?v=1766368071","url":"https:\/\/www.autocontrolglobal.com\/products\/tsxaez801-schneider-modicon-tsx-micro-input-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}