{"product_id":"tu830v1-abb-s800-i-o-termination-unit-brand-new-original","title":"TU830V1 ABB S800 I\/O Termination Unit Brand New Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB TU830V1 (3BSE013234R1) functions as a critical Extended Module Termination Unit (MTU) within the S800 I\/O system. This unit provides the physical interface and electrical connection points between field wiring and a wide array of S800 I\/O modules. It features 2x16 signal terminals, accommodating up to 16 channels with a maximum rated voltage of 50V. By centralizing 56 process connections into a compact, rail-mounted footprint, the TU830V1 simplifies cabinet organization and field instrument integration. We supply this unit as 100% brand new and original in factory packaging, ensuring the electrical integrity required for high-availability process automation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTU830V1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE013234R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtended Module Termination Unit (MTU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Terminals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 16 points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Process Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e56\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 ºC (131 ºF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS800 I\/O (AI810, AO810, DI810, DO810, etc.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe TU830V1 3BSE013234R1 optimizes field-to-controller connectivity by resolving complex wiring bottlenecks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Module Interoperability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis MTU supports a vast range of S800 analog and digital modules, including AI810, AO845, DI810, and DO880. This versatility allows engineers to standardize on a single termination type across multiple I\/O types, reducing spare parts inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2x16 terminal arrangement provides 56 distinct process connections in a space-saving profile. This design maximizes cabinet density, allowing for more I\/O points in a smaller footprint without sacrificing wire accessibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe extended MTU design allows for the \"hot-swapping\" of I\/O modules. Maintenance personnel can remove or replace the active I\/O module without disconnecting the field wiring, significantly reducing MTTR (Mean Time To Repair).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB rates the TU830V1 for continuous operation at 55 ºC (131 ºF). This thermal rating ensures reliable signal transmission in high-density control cabinets where heat accumulation often challenges lower-grade components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 50V rated voltage and robust terminal construction prevent signal leakage and crosstalk between channels, maintaining high-fidelity data acquisition for precision process control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich I\/O modules can I use with the TU830V1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TU830V1 is highly versatile. It works with a wide range of S800 modules, including Analog Inputs (AI810-AI845), Analog Outputs (AO810-AO845), Digital Inputs (DI810-DI885), Digital Outputs (DO810-DO880), and Pulse\/Frequency modules (DP820\/DP840).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit come with the original ABB factory warranty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply only brand new, original ABB hardware. This TU830V1 (3BSE013234R1) includes a full 12-month factory warranty and arrives in its original factory packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the standard lead time for this termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile we maintain stock for immediate needs, the estimated lead time typically ranges from 1 to 7 working days, depending on the current order volume.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many field wires can this unit accommodate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TU830V1 provides 56 process connections total, utilizing 2x16 signal terminals to manage the wiring for a 16-channel I\/O module efficiently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44120811208803,"sku":"TU830V1 3BSE013234R1","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/452._2b624a8a-5e9e-4969-b648-7c6673d8e04f.jpg?v=1776310538","url":"https:\/\/www.autocontrolglobal.com\/products\/tu830v1-abb-s800-i-o-termination-unit-brand-new-original","provider":"AutoControl Global","version":"1.0","type":"link"}