{"product_id":"turbine-termination-card-ge-is200tturh1c-speedtronic-mark-vi","title":"Turbine Termination Card | GE IS200TTURH1C Speedtronic Mark VI","description":"\u003ch2\u003eGE IS200TTURH1C Mark VI Turbine Control Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200TTURH1C\u003c\/strong\u003e is a turbine control terminal board manufactured by General Electric for the Speedtronic Mark VI turbine control system. Featuring the TTUR functional acronym, this board provides field-signal termination and electrical interfacing for turbine protection and control circuits. It pairs with compatible turbine I\/O packs such as the PTUR to support speed monitoring, overspeed protection, and signal routing within power generation systems.\u003c\/p\u003e\n\u003ch3\u003eSignal Termination and Protection Architecture\u003c\/h3\u003e\n\u003cp\u003eThe board accommodates multiple turbine inputs through dedicated hardware provisions, supporting up to 12 pulse rate device inputs, 3 overspeed trip signals, 3 onboard relays, 1 generator input, and 1 bus voltage input. Circuit connections are established using D-sub connectors, plug connectors, and physical terminal blocks. It supports jumper-selectable circuit configurations to adapt to specific system requirements.\u003c\/p\u003e\n\u003ch3\u003eRedundancy and System Integration\u003c\/h3\u003e\n\u003cp\u003eDesigned for installation within GE turbine control cabinets, the unit accommodates both simplex and Triple Modular Redundancy (TMR) architectures depending on system layout and configuration jumpers. Operating voltages and signal paths coordinate directly with associated control modules to ensure reliable signal conditioning and protection trip execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TTURH1C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTurbine Control Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eGE Speedtronic Mark VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTTUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eTurbine protection signal termination and interfacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported I\/O Pack\u003c\/td\u003e\n\u003ctd\u003ePTUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Rate Device Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverspeed Trip Signals\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Relays\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Voltage Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Modes\u003c\/td\u003e\n\u003ctd\u003eSimplex and TMR (jumper-configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eD-sub connectors, plug connectors, and terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eGE turbine control cabinet and associated hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 cm x 13.5 cm x 13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which I\/O packs are compatible with the IS200TTURH1C terminal board?\u003c\/p\u003e\n\u003cp\u003e A: The board works with compatible turbine I\/O modules, including the PTUR pack, to handle turbine speed and protection signals.\u003c\/p\u003e\n\u003cp\u003eQ: What redundancy configurations are supported by this terminal board?\u003c\/p\u003e\n\u003cp\u003e A: It supports both simplex and Triple Modular Redundancy (TMR) setups, which are established via jumper configurations and system layout.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":67794857328739,"sku":"IS200TTURH1C","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/324_96110f58-cc92-4971-b45e-94bf8d8dffd1.jpg?v=1792978672","url":"https:\/\/www.autocontrolglobal.com\/products\/turbine-termination-card-ge-is200tturh1c-speedtronic-mark-vi","provider":"AutoControl Global","version":"1.0","type":"link"}