UR8MH GE Multilin Universal Relay Series Datasheet & Technical Manual
Manufacturer: GE Fanuc
-
Part Number: UR8MH
Condition:New with Original Package
Product Type: Digital I/O Cards
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Multilin UR8MH Universal Relay Series Digital I/O Module
The GE Multilin UR8MH serves as the primary UR8MH Digital Input/Output Module utilized to execute specific technical tasks across GE Multilin UR Series platforms. The hardware functions as an addressable logic expansion board that intercepts physical status contacts from primary substation hardware while driving heavy‑duty mechanical trip command paths. The unit routes execution packets back and forth along the shared central rack data bus, translating raw high‑voltage interlock logic conditions and breaker position metrics into internal digital states.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | UR8MH |
| Brand | GE Multilin |
| Origin | Canada / USA |
| Weight | 0.7 kg |
| Dimensions | Standard UR chassis module size (6 x 4 in) / 3.8 x 11.5 x 4.5 cm |
| Operating Temp | -40 to 70 deg C |
| Power Consumption | Derived internally from the UR chassis backplane supply lines |
| Channel Topology | Multiple optically isolated inputs and Form-C output relays |
| Input Rating | Typical 24 VDC nominal sensing threshold thresholds |
| Contact Capacity | Form-C relay outputs rated at 8 A @ 250 VAC / 30 VDC resistive |
| Galvanic Isolation | Complete optical barrier isolation between I/O paths and CPU |
| Application Scope | Breaker automation control, automation interlocking, system alarms |
| Storage Temperature | -40 to 85 deg C |
Suffix Breakdown & Model Matrix
The UR8MH naming matrix defines the exact hardware selection options assigned to this specific digital input/output expansion interface configuration inside the Universal Relay hierarchy.
- UR: Universal Relay Series baseline platform system architecture identifier.
- 8M: High-density mixed digital input and mechanical relay output card layout assignment.
- H: Standard processing performance build and component revision parameter level.
Profinet / EtherNet/IP Deterministic Networks and I/O Density Scaling
The UR8MH relies on integrated hardware filtering circuits to optimize local signal processing without compromising baseline backplane bus communication velocity constraints. When expanding regional control loops during extensive I/O density scaling field upgrades, the processing engine registers status alterations asynchronously, allowing the state data to be parsed for upstream Profinet or EtherNet/IP deterministic networks via master communication cards. The module enforces strict firmware flash compatibility across legacy and current multi-slot chassis, locking signal delay margins down to deterministic ranges to prevent false interlock tripping profiles.
Frequently Asked Questions
Q: Can the UR8MH module be inserted into any open slot location within a Multilin UR Series chassis assembly?
A: No. Universal Relay chassis frames feature dedicated slot architectures. Digital I/O cards such as the UR8MH must lock directly into the specific expansion slots allocated by the master system configuration and memory map. Placing this module in an unassigned or invalid slot will prevent data bus registration and generate a system boot failure.
Q: Does the galvanic isolation on the digital inputs permit mixing different external voltage sources on the same card?
A: Yes, up to the maximum rated isolation threshold. The internal optical isolation pathways physically separate the wet field contact circuits from the central CPU processor. This design prevents common-mode surge voltage migration and permits independent external wetting voltage loops to interface with different groups of isolated input pins on the terminal assembly.
Field Installation Guidelines
- Chassis Power Demagnetization: Shut down all auxiliary power lines feeding the primary relay chassis assembly before attempting to service, extract, or insert the 0.7 kg module card framework.
- Module Seating Calibration: Slide the printed circuit board smoothly into the designated slot guide rails. Apply continuous horizontal force until the rear multi-pin male terminal assembly seats completely into the backplane plug-in block, then hand-tighten the integrated front faceplate mounting screws.
- Control Line Cable Routing: Keep external low-voltage digital sensing lines separated from high-voltage AC motor cables inside the wireways to eliminate common-mode noise induction and unintended signal state changes.
- Inductive Load Suppression: Install external snubber networks or freewheeling diodes directly across external DC inductive slave relay coils driven by the 8 A Form-C contact outputs to limit contact arcing and prolong contact operating life.