{"product_id":"usi-0002-fc-usi-0002-honeywell-safety-manager-module","title":"USI-0002 | FC-USI-0002 | Honeywell Safety Manager Module","description":"\u003ch3\u003e\u003cstrong\u003eHoneywell FC-USI-0002 Universal Safety Interface SM Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-USI-0002 (USI-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Universal Safety Interface module designed for the Honeywell Safety Manager and Fail-Safe Controller (FSC) systems. This multi-functional interface serves as a versatile bridge between field instrumentation and the safety processor, supporting a broad spectrum of signal types including analog (4-20 mA), digital I\/O, and temperature sensors (RTD\/Thermocouple). By centralizing these diverse inputs into a single hardware profile, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-USI-0002 (USI-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimplifies cabinet architecture and reduces spare part inventory requirements.\u003c\/p\u003e\n\u003cp\u003eEngineered for SIL 2 and SIL 3 environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-USI-0002 (USI-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures native HART protocol pass-through, allowing for remote calibration and diagnostics of smart field devices without interrupting safety logic. The module utilizes an FDX backplane communication protocol to maintain deterministic data exchange with the central controller. Its robust electrical isolation (up to 2500 V AC) and redundant 5 Vdc supply paths ensure that signal processing remains uncompromised even during localized electrical faults or power supply fluctuations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-USI-0002 (USI-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for high-precision safety monitoring:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-USI-0002\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUSI-0002\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Universal Safety Interface \/ System Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Safety Manager, FSC, Experion PKS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e: 8 Independently Configurable Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Support\u003c\/strong\u003e: 4–20 mA (Active\/Passive), HART 7 pass-through\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Support\u003c\/strong\u003e: RTD (Pt100\/Pt1000), Thermocouples (J, K, T, E, R, S)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Support\u003c\/strong\u003e: 24 Vdc Digital Input \/ Digital Output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.05% Full Scale (Analog inputs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e: 16-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: 100 ms for all channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e: 5 Vdc ±5% (via system backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Current\u003c\/strong\u003e: Max 1.2 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 1500 V AC channel-to-channel; 2500 V AC channel-to-ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -5 °C to +70 °C (+23°F to +158°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 21.2 cm x 17.6 cm x 3.52 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.7 kg (Unit) \/ 2.0 kg (Shipping)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e: \u0026gt;300,000 Hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: TÜV, CE, UL, CSA, FM, ATEX\/IECEx Zone 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44025351045219,"sku":"USI-0002","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/111._bdd31886-41c7-44c9-8f4e-4174393386dd.jpg?v=1772007102","url":"https:\/\/www.autocontrolglobal.com\/products\/usi-0002-fc-usi-0002-honeywell-safety-manager-module","provider":"AutoControl Global","version":"1.0","type":"link"}