{"product_id":"ve4002s1t2b5-emerson-discrete-output-card-new-original-stock","title":"VE4002S1T2B5 Emerson Discrete Output Card | New \u0026 Original Stock","description":"\u003ch1\u003eEmerson VE4002S1T2B5 DeltaV Series\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE4002S1T2B5\u003c\/strong\u003e serves as the primary \u003cstrong\u003eVE4002S1T2B5\u003c\/strong\u003e Discrete Output Card utilized to execute 32-channel discrete high-side switching tasks across DeltaV S-Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eVE4002S1T2B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.20 kg net module weight \/ 2.50 kg shipping weight configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e79 x 51 x 48 mm (module assembly footprint)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eInternal logic power drawn via DeltaV S-Series backplane interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eChannel Count\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e32 channels, high-side configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eMaximum Field Power\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e35 VDC @ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eTerminal Block Type\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eStandard I\/O screw-clamp execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eWire Size Capacity\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e12 to 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eIsolation Interface\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eGalvanic isolation between field-side and system-side paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eAtmospheric Environment\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eISA-S71.04 Class G3 conformal coating specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eMechanical Protection\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eIP20 base index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eII 3G Ex ec IIC Gc; Class I Division 2 Groups A-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module architecture functions alongside the primary process infrastructure to govern distributed control logic pathways, managing discrete outputs through field-side to system-side boundaries. Galvanic isolation circuits isolate the internal backplane components from transient field line surges up to the rated structural limits. Channel-to-channel isolation matrices prevent ground loop feedback propagation across the 32 discrete output paths. This electrical distribution blueprint ensures noise-immune discrete signal execution while operating adjacent to high-frequency instrumentation nodes using the 4-20 mA HART loop protocol.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific backplane load constraints and hot-swap limitations for this terminal module?\u003c\/p\u003e\n\u003cp\u003eA: The passive block components are structurally hot-swappable only when the associated active logic card is unseated from the slot and no field wiring loops remain energized. Performing a live chassis un-mating under field load conditions will disrupt the continuous 24 VDC output loop state across all 32 channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the high-side configuration react during an external circuit ground fault or short?\u003c\/p\u003e\n\u003cp\u003eA: The high-side switching topology cuts off output current at the power line if the system logic drops out. Individual channel-to-channel isolation safeguards the primary bus, preventing localized 24 VDC terminal shorts from drawing down system-side backplane power distribution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module interface onto the standard S-Series I\/O carrier track, ensuring the alignment pins engage the mechanical indexing slots.\u003c\/li\u003e\n\u003cli\u003eAlign the integrated rotary keying system to match the exact hardware profile code of the matching S-Series output processing module.\u003c\/li\u003e\n\u003cli\u003eInsert the 12 to 24 AWG discrete control wires into the screw-clamp terminal blocks, torquing the terminal points to standard industrial values.\u003c\/li\u003e\n\u003cli\u003eRoute all 24 VDC high-side discrete lines through dedicated low-voltage wiring ducts away from high-current AC motor leads.\u003c\/li\u003e\n\u003cli\u003eGround the system cable shielding layers at a single termination boundary on the instrumentation ground bus inside the cabinet housing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44212495712355,"sku":"VE4002S1T2B5","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/107.1_1964b25f-9342-44e8-8339-be8d4271e3e6.jpg?v=1779699206","url":"https:\/\/www.autocontrolglobal.com\/products\/ve4002s1t2b5-emerson-discrete-output-card-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}