{"product_id":"ve4003s2b2-emerson-analog-input-module-new-original-stock","title":"VE4003S2B2 Emerson Analog Input Module | New \u0026 Original Stock","description":"\u003ch1\u003eEmerson VE4003S2B2 DeltaV Analog Input Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for specific field instrumentation interface routing in DeltaV Distributed Control System networks, the \u003cstrong\u003eEmerson VE4003S2B2\u003c\/strong\u003e (\u003cstrong\u003eVE4003S2B2\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eVE4003S2B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.10 kg (Net module); 2.0 kg (Shipping standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e125 x 41 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e120 mA typical (150 mA maximum) @ 12 VDC LocalBus; 300 mA maximum @ 24 VDC field circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e8 channels (supporting 2-wire or 4-wire options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSignal Range\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e4 to 20 mA nominal span (1 to 23 mA full range with overrange checking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e0.1% of span over temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e0.05% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eFilter Rolloff Frequency\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-3 dB at 2.7 Hz; -20.5 dB at 0.5 times the sampling frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e100 VAC continuous field-to-system isolation (1700 VDC factory tested)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eIntegrated Protection\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e2.0 A optional fuse per assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eAirborne Contamination\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module architecture integrates standard 4-20 mA HART loop protocol capabilities across all 8 analog input channels, permitting the simultaneous transmission of digital process variables and diagnostic data over analog current signaling. Field-side to system-side circuits are decoupled through dedicated optical galvanic isolation elements verified by a 1700 VDC factory test block. This barrier design suppresses common-mode voltage fluctuations up to 100 VAC continuous, isolating the delicate LocalBus processing logic from external field grounding differentials and cross-channel electrical noise injection.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the restrictive parameters required to execute a hot-swap operation on this hardware?\u003c\/p\u003e\n\u003cp\u003eA: The VE4003S2B2 assembly permits hot-swapping under powered system conditions only when the corresponding I\/O card is completely disengaged from the front mating plane and no external field wiring distribution loops remain connected to the terminal paths.\u003c\/p\u003e\n\u003cp\u003eQ: How does the filtering subsystem process high-frequency interference on the 4-20 mA analog input loops?\u003c\/p\u003e\n\u003cp\u003eA: The input circuitry routes incoming signals through a low-pass filter establishing a -3 dB attenuation point at 2.7 Hz. This hardware curve suppresses high-frequency process noise and industrial induction frequencies, providing a -20.5 dB signal reduction at half the active sampling frequency.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module into the designated DeltaV S-Series I\/O carrier base, ensuring the mechanical rotary alignment key indexes correctly to block mismatched card insertions.\u003c\/li\u003e\n\u003cli\u003eConnect external loop wiring to the screw-clamp terminal array using wire gauges within the 12 to 24 AWG operating spectrum.\u003c\/li\u003e\n\u003cli\u003eRoute all 4-20 mA HART signaling cables inside low-voltage instrument raceways to avoid EMF induction from high-voltage motor supply runs.\u003c\/li\u003e\n\u003cli\u003eGround the instrument cable shielding wires at a single point to the primary structural enclosure instrument ground bus bar.\u003c\/li\u003e\n\u003cli\u003eVerify that the 2.0 A terminal protection fuses are fully seated in the terminal block housing before applying 24 VDC field circuit power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44211709640803,"sku":"VE4003S2B2","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/430._f9d9dfe0-ce9e-4e75-930a-55fa90f9e143.jpg?v=1779695416","url":"https:\/\/www.autocontrolglobal.com\/products\/ve4003s2b2-emerson-analog-input-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}