{"product_id":"ve4003s5b1-emerson-deltav-s-series-input-module","title":"VE4003S5B1 Emerson DeltaV S-Series Input Module","description":"\u003ch2\u003eEmerson VE4003S5B1 DeltaV Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE4003S5B1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE4003S5B1\u003c\/strong\u003e Input Module, operates as a dedicated hardware component for analog signal processing within Emerson DeltaV S-series platforms. The hardware converts process variables into 16-bit digital values, handling 4-20 mA loop signals and thermocouple millivolt inputs directly across the LocalBus backplane interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4003S5B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg to 0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 x 102 x 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLocalBus: 12 VDC at 100 mA to 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV S-series DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e32 isolated 4-20 mA channels or 8 thermocouple channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003ePass-through, point-to-point only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBussed Field Power Rating\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 32 mA (or 5 mA per thermocouple channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Resistance\u003c\/td\u003e\n\u003ctd\u003eShock: 10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection \u0026amp; Contaminants\u003c\/td\u003e\n\u003ctd\u003eIP20, ISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation and Galvanic Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe VE4003S5B1 incorporates onboard cold junction compensation (CJC) algorithms to correct thermal gradients across input terminals during thermocouple temperature measurement. Each signal channel provides complete channel-to-channel galvanic isolation to eliminate ground loops and reduce common-mode electrical noise in field wiring. In 4-20 mA operating modes, internal digital filtering preserves primary signal integrity while enabling point-to-point HART loop protocol pass-through communication for field device management.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the VE4003S5B1 maintain signal accuracy across temperature fluctuations?\u003c\/p\u003e\n\u003cp\u003eA: Integrated cold junction compensation senses thermal drift at the terminal block, dynamically adjusting the millivolt translation tables to preserve input precision.\u003c\/p\u003e\n\u003cp\u003eQ: Can the VE4003S5B1 module be removed or inserted under live power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Technicians can execute hot-swapping on powered DeltaV carriers without disrupting adjacent I\/O operations or damaging backplane communication lines.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms prevent electrical cross-talk between high-density channels?\u003c\/p\u003e\n\u003cp\u003eA: Complete channel-to-channel galvanic isolation isolates each loop electrically, suppressing transient voltage surges and common-mode noise across field lines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePress the VE4003S5B1 module securely onto the designated slot of the DeltaV S-series carrier until the locking mechanism fully engages the backplane connector. Fasten field wiring to the corresponding terminal block, keeping thermocouple millivolt cables and 4-20 mA current loops physically separated from AC distribution lines to limit inductive noise coupling. Terminate cable shielding at the main cabinet ground bar using a low-impedance single-point connection. Ensure the cabinet environment remains within the -40 to +70 deg C operating range before applying 24 VDC power.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43840697761891,"sku":"VE4003S5B1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/159_00920a56-89d5-4520-be65-936cbb7feff5.jpg?v=1763366967","url":"https:\/\/www.autocontrolglobal.com\/products\/ve4003s5b1-emerson-deltav-s-series-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}