{"product_id":"ve4003s6b1-deltav-kj3002x1-bf1-m-series-rtd-module","title":"VE4003S6B1 DeltaV | KJ3002X1-BF1 M-Series RTD Module","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE4003S6B1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Alternate Part Numbers:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3002X1-BF1\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12P1732X082\u003c\/strong\u003e) is a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-Channel RTD\/Ohm Analog Input Card\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV M-series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). This module specializes in converting resistance signals from Resistance Temperature Detectors (RTDs) and direct Ohm sources into digital temperature data for the DeltaV controller. By providing localized signal conditioning and A\/D conversion at the I\/O level, the VE4003S6B1 ensures accurate temperature monitoring for critical process equipment like heat exchangers, reactors, and bearing housings.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVE4003S6B1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem part number for the RTD\/Ohm Input Module assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKJ3002X1-BF1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufacturing hardware identification code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12P1732X082:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal Emerson component reference number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson Process Management\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE4003S6B1 \/ KJ3002X1-BF1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeltaV M-Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD (Pt100, Cu10, etc.) and Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 2000 Ohms (varies by RTD type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit A\/D conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEach channel galvanically isolated from the system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC via LocalBus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.10 lbs (0.5 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Thermal Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes 16-bit A\/D conversion to capture microscopic changes in resistance. This high resolution translates to precise temperature readings, allowing the DeltaV system to maintain tight control over temperature-sensitive chemical reactions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Linearization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VE4003S6B1 automatically linearizes standard RTD curves (such as Pt100) within the module hardware. This offloads the computational burden from the main CPU and ensures that the controller receives accurate, scaled engineering units (\u003cspan class=\"math-inline\"\u003e$^{\\circ}\\text{C}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$^{\\circ}\\text{F}$\u003c\/span\u003e) instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Lead-Wire Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe card supports 2-wire, 3-wire, and 4-wire RTD configurations. It automatically compensates for the resistance of the field wiring, eliminating measurement offsets caused by long cable runs between the sensor and the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integrity through Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGalvanic isolation between the field channels and the DeltaV LocalBus prevents electrical noise or ground faults in the field from damaging the controller. This architecture ensures that a single failed RTD sensor does not impact the entire I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Hot-Swappability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe M-series design permits the removal and replacement of the VE4003S6B1 while the system remains powered. This \"Plug-and-Play\" capability ensures that maintenance teams can update or repair temperature loops without affecting adjacent process monitoring points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the VE4003S6B1 still available if the manufacturer discontinued it?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. While officially discontinued by the manufacturer, we maintain stock of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits. These modules are factory-sealed and ready for immediate deployment in your existing M-series racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Which RTD types does this card support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The VE4003S6B1 supports common industrial RTDs including Pt100 (Platinum 100 Ohm), Pt1000, Cu10 (Copper), and various Nickel types. You can configure each of the 8 channels independently via the DeltaV Explorer software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I use this module to measure simple resistance (Ohms) instead of temperature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Absolutely. The module functions as a high-precision Ohmmeter. You can configure channels to report raw resistance values (up to 2000 Ohms), making it suitable for position sensors or other resistive transducers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does this card require a specific terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Yes. The VE4003S6B1 requires a standard M-series I\/O terminal block. Depending on your wiring preference, you can use either the mass terminal block or the individual screw terminal block for 3-wire or 4-wire RTD connections.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44109538230371,"sku":"VE4003S6B1","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/424._8ff29a25-6422-4935-b8c0-93e2e7ce55a0.jpg?v=1775791993","url":"https:\/\/www.autocontrolglobal.com\/products\/ve4003s6b1-deltav-kj3002x1-bf1-m-series-rtd-module","provider":"AutoControl Global","version":"1.0","type":"link"}