{"product_id":"ve4005s2b1-emerson-analog-output-card-new-original-stock","title":"VE4005S2B1 Emerson Analog Output Card | New \u0026 Original Stock","description":"\u003ch1\u003eEmerson VE4005S2B1 DeltaV S-Series Module\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE4005S2B1\u003c\/strong\u003e serves as the primary \u003cstrong\u003eVE4005S2B1\u003c\/strong\u003e Analog Output Card utilized to execute current loop signaling tasks across DeltaV Distributed Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eVE4005S2B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.10 kg (Net module); 2.0 kg (Shipping standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e125 x 41 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eHandled via DeltaV backplane interface (Field power distribution: 35 VDC @ 1 A maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e4 to 20 mA nominal span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eHART digital modulation on analog lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e18 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eIsolation Type\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eField-side to system-side galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eMounting Base\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eDeltaV S-Series I\/O carrier interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eScrew-clamp terminal array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eWire Size Spectrum\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e12 to 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003eISA-S71.04 Class G3 compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e10 g, 11 ms half-sine wave impulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003eVibration Limits\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e1 mm displacement (2 to 13.2 Hz); 0.7 g acceleration (13.2 to 150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module hardware provides direct physical termination for 8 analog output loops operating on the 4-20 mA HART loop protocol. Digital bi-directional FSK commands modulate directly onto the standard analog current signals to interface with field actuators and positioners without disrupting the primary analog variables. Galvanic isolation barriers separate the field wiring networks from the sensitive internal backplane logic processing nodes. Depending on the targeted S-Series I\/O card pairing, channel-to-channel isolation parameters prevent ground loop currents and cross-talk from degrading neighboring current loops when operating near high-induction industrial machinery.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the mandatory physical safety restrictions for hot-swapping this terminal block assembly?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping of the VE4005S2B1 block is strictly permitted only under the conditions that the corresponding S-Series I\/O module is completely extracted from the front faceplate and all active field wiring circuits are fully disconnected from the screw-clamp terminal array.\u003c\/p\u003e\n\u003cp\u003eQ: How does the mechanical configuration safeguard the module against incorrect card insertions?\u003c\/p\u003e\n\u003cp\u003eA: The hardware incorporates an adjustable rotary keying system on the chassis base. This keying dial must be aligned to match the mechanical interlock configuration profile of the assigned analog output card type, preventing physical damage caused by inserting mismatched I\/O hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the assembly directly onto the matching S-Series I\/O carrier structure, validating that the locking pins engage fully with the track rail.\u003c\/li\u003e\n\u003cli\u003eStrip 12 to 24 AWG field wires to the prescribed mechanical length and terminate them into the screw-clamp blocks at the designated torque specification.\u003c\/li\u003e\n\u003cli\u003eMaintain physical isolation between the 4-20 mA HART loop output paths and any AC power distribution or motor control wiring lines within the marshalling panel.\u003c\/li\u003e\n\u003cli\u003eConnect all cable shields to the designated single-point instrumentation ground bus bar inside the local control cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003eConfirm that the local operational environment remains within the certified Class I, Division 2, Groups A-D boundary criteria before energizing the 24 VDC loop distribution circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44211912474723,"sku":"VE4005S2B1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/432._cb701b64-85fd-4aa5-8c6c-c288da07c7f7.jpg?v=1779696276","url":"https:\/\/www.autocontrolglobal.com\/products\/ve4005s2b1-emerson-analog-output-card-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}