VE4006P2 Emerson DeltaV M-series Datasheet & Technical Manual
Manufacturer: Emerson
-
Part Number: VE4006P2
Condition:New with Original Package
Product Type: Serial Interface Cards
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Emerson VE4006P2 DeltaV M-series Card
The Emerson VE4006P2 serves as the primary VE4006P2 Serial Interface Card utilized to execute RS232 and RS485 data conversion across Emerson DeltaV M-series control system platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | VE4006P2 |
| Brand | Emerson |
| Origin | USA |
| Weight | Standard M-series module weight |
| Dimensions | Standard M-series footprint |
| Operating Temp | -40 to +70 deg C |
| Storage Temp | -40 to +85 deg C |
| Power Consumption | Base backplane current draw |
| Communication Ports | 2 ports (configurable as RS232 or RS485) |
| Supported Protocols | RS232, RS485 |
| Baud Rate Range | 300 to 115,200 bps |
| Data Set Capacity | Up to 32 data sets per card (16 data sets per port) |
| System Compatibility | DeltaV MQ, MX, and PK controllers |
| Contaminant Protection | ISA-S71.04-1985 Class G3 (conformal coated) |
| Mounting | Standard DeltaV carrier slot |
Process Control and DCS Instrumentation Features
The serial interface card architecture implements localized channel-to-channel isolation between ports to block transient voltage spikes from traversing the backplane bus matrix. The integrated physical layer drivers manage asynchronous byte streams over standard 4-20 mA HART loop protocol environments via auxiliary gateways or direct serial networks. This setup minimizes protocol latency while executing Modbus or custom master/slave polling loops, preventing signal degradation in high electromagnetic interference areas.
Frequently Asked Questions
Q: How is the serial protocol configuration managed on each communication port?
A: Physical selection between RS232 and RS485 modes is governed via software assignments within the DeltaV engineering environment, while the mechanical keying system ensures proper alignment on the carrier.
Q: What are the limits for concurrent data collection on this interface hardware?
A: The module architecture is hardcoded to buffer a maximum of 32 total datasets per card, allocated evenly at a maximum of 16 datasets per serial port.
Q: Does the conformal coating alter the thermal management requirements of the card?
A: No. The factory-applied conformal coating provides ISA-S71.04-1985 Class G3 environmental protection without reducing the rated -40 to +70 deg C operational threshold.
Field Installation Guidelines
- Carrier Insertion: Verify the physical keying position on the standard DeltaV carrier before sliding the card into the slot to prevent connection pins from binding.
- Shield Termination: Ground the RS485/RS232 signal cable shields at a single point on the chassis ground rail to prevent common-mode voltage offsets.
- Line Termination: Apply external 120 Ohm termination resistors at the physical ends of long RS485 network segments to eliminate signal reflections.
- Cable Separation: Maintain a minimum physical distance between the serial data wiring and high-current AC power cables inside the wire ducts to reduce cross-induction.