VE4006P2 Emerson DeltaV M-series Datasheet & Technical Manual
VE4006P2 Emerson DeltaV M-series Datasheet & Technical Manual
VE4006P2 Emerson DeltaV M-series Datasheet & Technical Manual
/ 3

VE4006P2 Emerson DeltaV M-series Datasheet & Technical Manual

  • Manufacturer: Emerson

  • Part Number: VE4006P2

  • Condition:New with Original Package

  • Product Type: Serial Interface Cards

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson VE4006P2 DeltaV M-series Card

The Emerson VE4006P2 serves as the primary VE4006P2 Serial Interface Card utilized to execute RS232 and RS485 data conversion across Emerson DeltaV M-series control system platforms.

Hardware Specifications

Parameter Specification
Model VE4006P2
Brand Emerson
Origin USA
Weight Standard M-series module weight
Dimensions Standard M-series footprint
Operating Temp -40 to +70 deg C
Storage Temp -40 to +85 deg C
Power Consumption Base backplane current draw
Communication Ports 2 ports (configurable as RS232 or RS485)
Supported Protocols RS232, RS485
Baud Rate Range 300 to 115,200 bps
Data Set Capacity Up to 32 data sets per card (16 data sets per port)
System Compatibility DeltaV MQ, MX, and PK controllers
Contaminant Protection ISA-S71.04-1985 Class G3 (conformal coated)
Mounting Standard DeltaV carrier slot

Process Control and DCS Instrumentation Features

The serial interface card architecture implements localized channel-to-channel isolation between ports to block transient voltage spikes from traversing the backplane bus matrix. The integrated physical layer drivers manage asynchronous byte streams over standard 4-20 mA HART loop protocol environments via auxiliary gateways or direct serial networks. This setup minimizes protocol latency while executing Modbus or custom master/slave polling loops, preventing signal degradation in high electromagnetic interference areas.

Frequently Asked Questions

Q: How is the serial protocol configuration managed on each communication port?

A: Physical selection between RS232 and RS485 modes is governed via software assignments within the DeltaV engineering environment, while the mechanical keying system ensures proper alignment on the carrier.

Q: What are the limits for concurrent data collection on this interface hardware?

A: The module architecture is hardcoded to buffer a maximum of 32 total datasets per card, allocated evenly at a maximum of 16 datasets per serial port.

Q: Does the conformal coating alter the thermal management requirements of the card?

A: No. The factory-applied conformal coating provides ISA-S71.04-1985 Class G3 environmental protection without reducing the rated -40 to +70 deg C operational threshold.

Field Installation Guidelines

  • Carrier Insertion: Verify the physical keying position on the standard DeltaV carrier before sliding the card into the slot to prevent connection pins from binding.
  • Shield Termination: Ground the RS485/RS232 signal cable shields at a single point on the chassis ground rail to prevent common-mode voltage offsets.
  • Line Termination: Apply external 120 Ohm termination resistors at the physical ends of long RS485 network segments to eliminate signal reflections.
  • Cable Separation: Maintain a minimum physical distance between the serial data wiring and high-current AC power cables inside the wire ducts to reduce cross-induction.
You may also like