{"product_id":"ve4035s2b1-kj3221x1-ba1-emerson-deltav-series-2-analog-input-module","title":"VE4035S2B1 KJ3221X1-BA1 Emerson DeltaV Series 2 Analog Input Module","description":"\u003ch2\u003eEmerson VE4035S2B1 DeltaV Series 2 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE4035S2B1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKJ3221X1-BA1\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for 16-channel analog signal acquisition within Emerson DeltaV DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4035S2B1 (Part Number: KJ3221X1-BA1 \/ KJ3221X1-EA1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 x 102 x 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA (LocalBus), 12 VDC at 300 mA (Bussed Field Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003ePass-through, point-to-point only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (2-13.2 Hz), 0.7 g (13.2-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, ATEX, IECEx (Zone 2 \/ Class I Div. 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Isolation Features\u003c\/h3\u003e\n\u003cp\u003eThe module delivers 16-bit resolution across 16 channels, enabling continuous acquisition of 4-20 mA HART loop protocol signals from field transmitters. Integrated channel-to-channel isolation prevents differential ground loops from corrupting measurement values or propagating transient voltage noise to the LocalBus logic carrier. Internal cold junction compensation (CJC) routing on adjacent baseplates supports stable temperature conversions, maintaining loop calibration integrity across high-density industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary backplane current draws for the VE4035S2B1 module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 12 VDC at 150 mA from the internal LocalBus rail and 12 VDC at 300 mA from the bussed field power connection, delivering up to 24 VDC at 32 mA per field circuit.\u003c\/p\u003e\n\u003cp\u003eQ: Does the VE4035S2B1 support hot-swappable replacement on active DeltaV baseplates?\u003c\/p\u003e\n\u003cp\u003eA: Engineers can perform hot-swappable installation and removal of the module on energized DeltaV I\/O baseplates without disrupting adjacent I\/O slots or interrupting backplane communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSeat the module firmly onto the designated DeltaV carrier slot until the top and bottom mechanical latches click into place.\u003c\/li\u003e\n\u003cli\u003eRoute all 4-20 mA field transmitter wiring through shielded twisted-pair cables to preserve 16-bit analog-to-digital conversion accuracy.\u003c\/li\u003e\n\u003cli\u003eTerminate signal cable shields at a single point on the cabinet instrument ground bar to prevent circulating ground currents.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between 24 VDC analog input field wiring and high-voltage AC power cables in cabinet wireways.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43840921141347,"sku":"VE4035S2B1 KJ3221X1-BA1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/170_cc68bff6-9867-427c-967e-027ca6dd5720.jpg?v=1763372933","url":"https:\/\/www.autocontrolglobal.com\/products\/ve4035s2b1-kj3221x1-ba1-emerson-deltav-series-2-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}