VE4050S2K1C1 Emerson DeltaV S-Series I/O Interface Carrier
Manufacturer: Emerson
-
Part Number: VE4050S2K1C1
Condition:New with Original Package
Product Type: I/O Interface Carriers
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Emerson VE4050S2K1C1 DeltaV S-Series I/O Carrier
The Emerson VE4050S2K1C1, also cataloged as the VE4050S2K1C1 I/O Carrier, operates as a dedicated hardware component for field signal backplane routing and shield grounding within Emerson DeltaV S-Series control networks.
Suffix Breakdown & Model Matrix
The model number VE4050S2K1C1 represents a distinct hardware combination within the DeltaV S-Series system carrier assembly. The primary sequence defines the core carrier base structure, while the trailing suffix designation (S2K1C1) indicates the inclusion of a factory-integrated carrier shield bar and extension cable assembly for high-density panel routing.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | VE4050S2K1C1 |
| Brand | Emerson |
| Origin | USA |
| Weight | 4.54 kg (10.01 lbs) |
| Dimensions | Standard S-Series Carrier Dimensions |
| Operating Temp | -10 to +50 deg C |
| Power Consumption | Passive System Backplane Carrier Bus |
| Product Type | I/O Interface Carrier |
| System Compatibility | Emerson DeltaV S-Series DCS |
| Connection Type | Screw Terminal Interface |
| Integrated Hardware | Carrier Shield Bar and Extension Cable |
| Storage Temp | -40 to +85 deg C |
| Humidity Range | 5% to 95%, non-condensing |
| Mounting Options | Panel Mount or 35 mm DIN Rail |
Channel-to-Channel Isolation & 4-20 mA HART Loop Protocol Capabilities
The Emerson VE4050S2K1C1 carrier establishes physical bus pathways for digital communications and analog instrumentation, supporting 4-20 mA HART loop protocol signals across dense I/O channels. Onboard passive backplane lines preserve channel-to-channel isolation between adjacent module slots, preventing ground potential shifts from degrading measurement precision. The integrated carrier shield bar provides a low-impedance grounding rail to drain stray electromagnetic interference (EMI) prior to signal processing.
Frequently Asked Questions
Q: Does the Emerson VE4050S2K1C1 support live insertion and removal of I/O modules?
A: Yes, the carrier backplane architecture permits hot-swapping individual I/O modules without interrupting power execution or communication signals on neighboring module channels.
Q: How is field cable shielding grounded on the VE4050S2K1C1 assembly?
A: Cable shields connect directly to the factory-installed carrier shield bar, providing a single-point earth ground termination to eliminate high-frequency electrical noise.
Q: What mounting configurations does the physical carrier frame support?
A: Technicians can secure the assembly using standard 35 mm DIN rail clips or attach the rigid frame directly to a cabinet panel backplate using mechanical fasteners.
Field Installation Guidelines
Technicians must verify system power status before mounting or wiring the Emerson VE4050S2K1C1 carrier assembly. Ensure the enclosure main grounding bus connects to earth ground using a short, low-impedance copper conductor.
First, lock the carrier frame onto the 35 mm DIN rail or secure it to the panel using appropriate mounting screws. Maintain a minimum vertical clearance of 100 mm above and below the carrier to permit natural convective airflow across installed modules.
Second, terminate all field wiring at the screw terminal connectors, torquing terminal screws according to manufacturer enclosure specifications. Fasten all incoming signal shield wires securely to the carrier shield bar to maintain continuous noise suppression.