VE4055S2C0 Emerson Vertical Carrier | New & Original Stock
VE4055S2C0 Emerson Vertical Carrier | New & Original Stock
VE4055S2C0 Emerson Vertical Carrier | New & Original Stock
/ 3

VE4055S2C0 Emerson Vertical Carrier | New & Original Stock

  • Manufacturer: Emerson

  • Part Number: VE4055S2C0

  • Condition:New with Original Package

  • Product Type: DCS Baseplates and Carriers

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson VE4055S2C0 DeltaV Vertical Carrier

The Emerson VE4055S2C0, also cataloged as the Emerson VE4055S2C0 Right 8-Wide Vertical Carrier, operates as a dedicated hardware component for structural support and electrical routing within Emerson DeltaV Distributed Control System platforms.

Hardware Specifications

Parameter Specification
Model VE4055S2C0
Brand Emerson
Origin USA
Weight 0.6 to 0.8 kg
Dimensions 107 mm x 41 mm x 105 mm
Operating Temp -40 to +70 deg C
Storage Temp -40 to +85 deg C
Humidity Range 5% to 95%, non-condensing
Product Type Right 8-Wide Vertical Carrier
System Compatibility DeltaV DCS
Mounting Orientation Vertical
Module Capacity 8 I/O modules
Material Industrial-grade composite/plastic
Power Consumption Base backplane draw only (dependent on attached load cards)
Certifications CE, COO

Process Control and DCS Instrumentation Features

The carrier implements dedicated signal routing and channel-to-channel isolation safeguards when interfacing with active I/O electronics. It incorporates physical provisions for 4-20 mA HART loop protocol pass-through, maintaining signal integrity across the internal bus structure. To mitigate high-frequency interference across adjacent channels, the backplane circuit architecture features optimized trace separation, minimizing potential channel-to-channel crosstalk during multi-variable analog data acquisition.

Frequently Asked Questions

Q: What is the maximum physical module capacity supported by the carrier?

A: The hardware architecture accommodates a maximum configuration of 8 side-by-side I/O modules on a single carrier assembly.

Q: Are there specific installation restrictions regarding orientation?

A: Yes. The structural layout and ventilation paths require direct vertical mounting inside the enclosure or control cabinet to maintain specified operational performance.

Q: Does the carrier provide integrated local power conversion?

A: No. The unit acts as a passive distribution and routing backplane, directing bulk system power and communication lines to the individual active I/O modules.

Field Installation Guidelines

  • Mounting Alignment: Ensure the carrier is securely attached to the vertical DIN rail or backpanel using standard mounting hardware to prevent mechanical stress on internal bus connections.
  • Wiring and Routing: Maintain separate routing paths for high-voltage power lines and low-voltage 4-20 mA signal wires to prevent electrical noise coupling.
  • Grounding Protocols: Connect the carrier ground point to the main system instrument ground bus using a low-impedance copper conductor.
  • Thermal Management: Leave adequate clearance at the top and bottom of the vertical assembly to enable unobstructed convection cooling within the cabinet.