{"product_id":"versamax-micro-ic200ual005-ge-23-point-plc-module","title":"VersaMax Micro IC200UAL005 GE 23 Point PLC Module","description":"\u003ch2\u003eGE IC200UAL005 VersaMax Micro 23 Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete and analog processing in small machine control environments, the \u003cstrong\u003eGE IC200UAL005\u003c\/strong\u003e (\u003cstrong\u003eIC200UAL005\u003c\/strong\u003e Micro 23 PLC) provides direct physical\/electrical execution. This compact programmable logic controller integrates discrete I\/O, multi-channel analog interfaces, and serial communication pathways onto a single 24 VDC powered platform. Operating within the VersaMax Micro hardware family, the unit executes real-time ladder logic while directly terminating field device instrumentation through its onboard physical terminal strip.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UAL005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE) \/ VersaMax Micro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg (1.50 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 76 mm x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 W (Input Power Supply Rating at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eVersaMax Micro 23 Point PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-20% \/ +25%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete DC Inputs\u003c\/td\u003e\n\u003ctd\u003e13 channels (24 VDC, 0 to 30 VDC range, 7.5 mA typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e9 channels (Form A relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete DC Output\u003c\/td\u003e\n\u003ctd\u003e1 channel (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e2 channels (0 to 10 VDC or 4 to 20 mA, 12-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e1 channel (0 to 10 VDC or 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e1 A at 30 V DC (10 ms duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary DC Output\u003c\/td\u003e\n\u003ctd\u003e24 VDC (200 mA maximum load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2 built-in serial ports (RS-232, RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counters\u003c\/td\u003e\n\u003ctd\u003eUp to 4 Type A counters or 1 Type A + 1 Type B (10 kHz maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWM Output\u003c\/td\u003e\n\u003ctd\u003e1 channel (5 kHz maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS field-to-logic, 500 V RMS between groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eVersaPro 1.1 or higher, Proficy Machine Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200UAL005 leverages embedded CPU firmware to maintain real-time program execution with a typical scan rate of 1.1 ms per key logic cycle. Firmware flash compatibility ensures seamless logic synchronization when deploying code compiled via Proficy Machine Edition or VersaPro platforms. For applications requiring footprint expansion beyond the core 23 points, the controller supports local I\/O density scaling. Engineers can cascade up to 4 expansion modules via the right-side expansion bus port, increasing system capacity up to 135 total I\/O points without degrading local backplane timing structures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How much current can the auxiliary 24 VDC output terminal provide to external field sensors?\u003c\/p\u003e\n\u003cp\u003eA: The onboard auxiliary 24 VDC supply delivers a maximum of 200 mA. Connecting field devices that exceed this current threshold will trip internal thermal protection circuits, requiring an external 24 VDC power supply for additional transducer loops.\u003c\/p\u003e\n\u003cp\u003eQ: What programming packages support configuration and downloading to the IC200UAL005?\u003c\/p\u003e\n\u003cp\u003eA: The controller supports logic development, hardware configuration, and firmware monitoring through VersaPro software version 1.1 or higher, as well as Proficy Machine Edition Logic Developer.\u003c\/p\u003e\n\u003cp\u003eQ: Can the onboard analog input channels accept 4-20 mA current signals directly?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 2 built-in analog input channels support 12-bit conversion for both 0-10 VDC voltage modes and 4-20 mA current loop configurations based on physical wiring connections and software register setup.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting\u003c\/strong\u003e: Snap the controller securely onto a standard 35 mm DIN rail or fasten it to a metal backplate using the mounting tabs. Ensure structural clearance of at least 50 mm above and below the unit for convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Wiring\u003c\/strong\u003e: Connect the 24 VDC system power source to the designated input terminals using twisted-pair wire. Verify line polarity before energizing to prevent input power section damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Signal Shielding\u003c\/strong\u003e: Terminate all 0-10 VDC and 4-20 mA analog input\/output wiring using shielded twisted-pair cables. Ground the shield drain wire at one end only to prevent ground loop noise from corrupting 12-bit resolution data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Suppression\u003c\/strong\u003e: Install external flyback diodes across DC inductive loads or RC snubbers across AC relay output loads. Relying solely on internal relay contacts without surge suppression risks contact pitting and premature relay failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port Noise Separation\u003c\/strong\u003e: Maintain physical separation between RS-232\/RS-485 serial communication cables and high-voltage AC power conductors within cable trays and control panel ducting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44524091015267,"sku":"IC200UAL005","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/189._5792b277-bd8d-4f74-bee1-ea80d756902a.jpg?v=1787884221","url":"https:\/\/www.autocontrolglobal.com\/products\/versamax-micro-ic200ual005-ge-23-point-plc-module","provider":"AutoControl Global","version":"1.0","type":"link"}