VME Vibration Input Card | GE IS200VVIBH1CAB Mark VI
VME Vibration Input Card | GE IS200VVIBH1CAB Mark VI
VME Vibration Input Card | GE IS200VVIBH1CAB Mark VI
/ 3

VME Vibration Input Card | GE IS200VVIBH1CAB Mark VI

  • Manufacturer: GE Fanuc

  • Part Number: IS200VVIBH1C AB

  • Condition:New with Original Package

  • Product Type: Vibration Input Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE IS200VVIBH1CAB Mark VI VME Vibration Board

The GE IS200VVIBH1CAB, also cataloged as the IS200VVIB Vibration Board, operates as a dedicated hardware component for vibration signal conditioning and acquisition within GE Mark VI Turbine Control System platforms. The 6U VME board processes analog signals from 8 input channels connected to proximity probes and accelerometers, converting raw dynamic sensor data across a +/-24 VDC input range into real-time digital parameters for machinery protection. Utilizing integrated active filtering, signal amplification, and 1500 VDC channel-to-bus galvanic isolation, the hardware conditions field transducer loops prior to transmitting diagnostic values across the system backplane.

Hardware Specifications

Parameter Specification
Model IS200VVIBH1CAB
Brand GE
Origin USA
Weight 0.3 kg
Dimensions 2.1 cm x 18.8 cm x 26.2 cm (Standard 6U VME Form Factor)
Operating Temp 0 deg C to +60 deg C
Power Consumption +5 VDC via Backplane Bus
System Compatibility GE Mark VI Turbine Control System
Channel Density 8 Vibration Input Channels
Supported Sensors Proximity Probes (e.g., Bently Nevada), Accelerometers
Signal Range +/-24 VDC Input Range
Isolation 1500 VDC Channel-to-Bus Isolation
Diagnostics Integrated Status LED Indicators

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The GE IS200VVIBH1CAB communicates across the high-speed VME backplane bus to ensure real-time data transfer without introducing transmission latencies into critical trip loops. The board executes onboard analog-to-digital conversion, synchronizing sampled vibration values with the main turbine controller at fixed deterministic intervals. Embedded firmware flash compatibility maintains seamless functional alignment across different revision levels of the GE Mark VI software environment, eliminating execution mismatches during board replacement or system expansion.

Frequently Asked Questions

Q: How does the VVIB board interface with Bently Nevada proximity probes on field machinery?

A: The board receives +/-24 VDC raw transducer signals from the field terminal block, providing internal signal attenuation and anti-aliasing filtering before routing data to the VME backplane processor.

Q: Does the board support hot-swap replacement inside an active Mark VI rack?

A: Field maintenance requires powering down the local rack segment or locking out associated protection loops prior to removal to avoid backplane communication disruption during card extraction.

Q: How do technicians verify individual channel status during initial field setup?

A: Onboard LED indicators display channel operational health, power supply rails, and probe line integrity, enabling direct visual confirmation of physical wiring continuity without external test equipment.

Field Installation Guidelines

Execute the following physical installation steps during module replacement or system commissioning:

  1. VME Slot Alignment: Slide the 6U board card edges carefully into the designated VME rack card guides, maintaining perpendicular alignment with the backplane connectors.
  2. Backplane Insertion: Press the upper and lower injector/ejector handles simultaneously to seat the multi-pin DIN backplane connectors without bending pin contacts.
  3. Handle Locking: Tighten the top and bottom retaining screws on the front panel to anchor the board frame to the rack chassis, securing the chassis ground connection.
  4. Shield Wire Routing: Ensure sensor drain wires from proximity probe cables terminate at the dedicated system ground bar, maintaining isolated single-point grounding to suppress cross-talk.
  5. Transducer Voltage Verification: Measure power supply delivery to field proximity probes at the terminal strip to verify target bias voltages remain within +/-24 VDC operating limits.
You may also like