{"product_id":"vme-vibration-input-card-ge-is200vvibh1cab-mark-vi","title":"VME Vibration Input Card | GE IS200VVIBH1CAB Mark VI","description":"\u003ch2\u003eGE IS200VVIBH1CAB Mark VI VME Vibration Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200VVIBH1CAB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200VVIB\u003c\/strong\u003e Vibration Board, operates as a dedicated hardware component for vibration signal conditioning and acquisition within GE Mark VI Turbine Control System platforms. The 6U VME board processes analog signals from 8 input channels connected to proximity probes and accelerometers, converting raw dynamic sensor data across a +\/-24 VDC input range into real-time digital parameters for machinery protection. Utilizing integrated active filtering, signal amplification, and 1500 VDC channel-to-bus galvanic isolation, the hardware conditions field transducer loops prior to transmitting diagnostic values across the system backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VVIBH1CAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.1 cm x 18.8 cm x 26.2 cm (Standard 6U VME Form Factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC via Backplane Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e8 Vibration Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003eProximity Probes (e.g., Bently Nevada), Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e+\/-24 VDC Input Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC Channel-to-Bus Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eIntegrated Status LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200VVIBH1CAB\u003c\/strong\u003e communicates across the high-speed VME backplane bus to ensure real-time data transfer without introducing transmission latencies into critical trip loops. The board executes onboard analog-to-digital conversion, synchronizing sampled vibration values with the main turbine controller at fixed deterministic intervals. Embedded firmware flash compatibility maintains seamless functional alignment across different revision levels of the GE Mark VI software environment, eliminating execution mismatches during board replacement or system expansion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the VVIB board interface with Bently Nevada proximity probes on field machinery?\u003c\/p\u003e\n\u003cp\u003eA: The board receives +\/-24 VDC raw transducer signals from the field terminal block, providing internal signal attenuation and anti-aliasing filtering before routing data to the VME backplane processor.\u003c\/p\u003e\n\u003cp\u003eQ: Does the board support hot-swap replacement inside an active Mark VI rack?\u003c\/p\u003e\n\u003cp\u003eA: Field maintenance requires powering down the local rack segment or locking out associated protection loops prior to removal to avoid backplane communication disruption during card extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How do technicians verify individual channel status during initial field setup?\u003c\/p\u003e\n\u003cp\u003eA: Onboard LED indicators display channel operational health, power supply rails, and probe line integrity, enabling direct visual confirmation of physical wiring continuity without external test equipment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eExecute the following physical installation steps during module replacement or system commissioning:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVME Slot Alignment\u003c\/strong\u003e: Slide the 6U board card edges carefully into the designated VME rack card guides, maintaining perpendicular alignment with the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion\u003c\/strong\u003e: Press the upper and lower injector\/ejector handles simultaneously to seat the multi-pin DIN backplane connectors without bending pin contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandle Locking\u003c\/strong\u003e: Tighten the top and bottom retaining screws on the front panel to anchor the board frame to the rack chassis, securing the chassis ground connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Wire Routing\u003c\/strong\u003e: Ensure sensor drain wires from proximity probe cables terminate at the dedicated system ground bar, maintaining isolated single-point grounding to suppress cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Voltage Verification\u003c\/strong\u003e: Measure power supply delivery to field proximity probes at the terminal strip to verify target bias voltages remain within +\/-24 VDC operating limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44451767517283,"sku":"IS200VVIBH1C AB","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/141_594c1467-dd4b-4dd7-ac18-10744c2d6351.jpg?v=1786005453","url":"https:\/\/www.autocontrolglobal.com\/products\/vme-vibration-input-card-ge-is200vvibh1cab-mark-vi","provider":"AutoControl Global","version":"1.0","type":"link"}