{"product_id":"woodward-8262-959-electronic-governor-actuator-engine-control","title":"Woodward 8262-959 Electronic Governor Actuator Engine Control","description":"\u003ch2\u003eWoodward 8262-959 Electronic Actuator Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for fuel rack and throttle valve positional execution in engine governor networks, the \u003cstrong\u003eWoodward 8262-959\u003c\/strong\u003e (\u003cstrong\u003e8262-959\u003c\/strong\u003e Electronic Actuator Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eElectrical Input\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMechanical Rotation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8262-959\u003c\/td\u003e\n\u003ctd\u003eStandard Factory Build\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003ctd\u003e35 deg to 40 deg rotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8262-959\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 to 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 x 120 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Type\u003c\/td\u003e\n\u003ctd\u003eProportional solenoid actuator with integral linkage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Travel\u003c\/td\u003e\n\u003ctd\u003e35 deg to 40 deg mechanical rotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Inputs\u003c\/td\u003e\n\u003ctd\u003eCompatible with Woodward 2301 and 2500 series governors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response \u0026amp; Dynamic Stability\u003c\/h3\u003e\n\u003cp\u003eThe internal proportional solenoid assembly executes dynamic rotational position adjustments between 35 deg and 40 deg to optimize the actuator loop feedback response during high-transient load steps. Driven directly by signals from Woodward 2301 or 2500 series control platforms, the hardware converts current inputs into proportional mechanical force, overcoming link stiction without dynamic overshoot. Internal thermal heat sink dissipation profiles efficiently channel internal heat away from the solenoid coil, maintaining force consistency and preventing thermal drift across the entire -40 to +85 deg C temperature envelope.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the proportional solenoid interface with existing Woodward 2301 or 2500 series control loops?\u003c\/p\u003e\n\u003cp\u003eA: The solenoid coil receives a variable control current from the governor driver output, converting the current directly into proportional shaft rotation to regulate fuel rack positioning.\u003c\/p\u003e\n\u003cp\u003eQ: What installation steps prevent mechanical linkage binding across the 35 to 40 deg travel range?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must align the actuator output lever and the engine fuel rack linkage in a single plane, checking manually for zero mechanical slop or binding before connecting the control link.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit rigidly to the engine bracket using high-tensile bolts to withstand operational vibration. Connect the 24 VDC power supply and governor output driver lines using twisted, shielded pair wiring. Electrical installers must ground the cable shield drain wire at the electronic governor bus bar only, preventing circulating ground current loops. Verify that the mechanical linkage operates freely through the full 35 deg to 40 deg rotation stroke prior to starting the engine.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43906614722659,"sku":"8262-959","price":310.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/43_a0b12f67-e0ce-44f7-8abe-da3349c95fbd.jpg?v=1766460655","url":"https:\/\/www.autocontrolglobal.com\/products\/woodward-8262-959-electronic-governor-actuator-engine-control","provider":"AutoControl Global","version":"1.0","type":"link"}