{"product_id":"x-fta00201-hima-process-safety-field-termination-module","title":"X-FTA00201 HIMA Process Safety Field Termination Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA X-FTA00201 functions as a high-density, safety-related Field Termination Assembly (FTA) engineered specifically for the HIMax safety PLC architecture. This hardware interface streamlines, organizes, and secures the raw wiring paths coming from field instruments before they reach the main I\/O modules. Control panel builders deploy this termination board inside marshalling enclosures to establish a clean boundary between field wiring loops and critical safety infrastructure.\u003c\/p\u003e\n\u003cp\u003eThe electronic layout accommodates both discrete digital signals and precision analog variables, mapping them directly to matching HIMax I\/O processing cards via standardized system cables. By positioning this termination asset at the cabinet entry point, plant networks shield their sensitive safety processors from external field anomalies. It plays a vital role in Emergency Shutdown (ESD) configurations, Burner Management Systems (BMS), and Fire and Gas (F\u0026amp;G) protection matrices.\u003c\/p\u003e\n\u003cp\u003eWe distribute this essential hardware termination board exclusively in \u003cstrong\u003e100% brand new, original, and factory-sealed\u003c\/strong\u003e condition. This uncompromising delivery standard ensures perfect screw-terminal threads, pristine galvanic insulation barriers, and unmarred printed circuit tracks that satisfy rigorous functional safety lifespans.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the precise electrical, mechanical, safety, and environmental parameters for the HIMA X-FTA00201 assembly board. All values utilize standard ASCII formatting.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eHIMA Paul Hildebrandt GmbH (Germany)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eModel Number\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eX-FTA00201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eCore System Platform\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eHIMax Safety PLC System Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModule Equipment Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eField Termination Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003ePrimary Allocation Task\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eExternal wiring interface block for I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eHandled Signal Formats\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eDigital and Analog signals (Determined by master I\/O card)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eIsolation Technology\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eGalvanic separation between field connectors and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eNominal Operating Power\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e24 VDC nominal supply line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eFunctional Safety Threshold\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eSIL 3 Certified compliant according to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eCabinet Mounting Profiles\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eStandard 35mm DIN Rail or Direct Backpanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eEnclosure Form Dimensions\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e100 mm x 80 mm x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eNet Component Hardware Weight\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e0.7 kg (1.54 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eAmbient Operational Temperature\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-20 to +60 degrees Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eSafe Storage Temperature Window\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40 to +85 degrees Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eKey Industry Environments\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eOil and Gas, Chemical Refineries, Power Generation Plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined Marshalling Cabinet Organization:\u003c\/strong\u003e The structured layout replaces messy point-to-point field splices with organized terminal segments. This centralization reduces cable path complexity, minimizes installation footprint, and speeds up loop checkout tasks during plant commissioning phases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Protection Interface Barrier:\u003c\/strong\u003e Built-in galvanic isolation channels intercept electrical path disruption right at the terminal block boundary. This barrier blocks inductive transient spikes, ground potential differences, and lightning induction currents, keeping the core HIMax I\/O module processing logic safe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-Directional Mixed Signal Adaptability:\u003c\/strong\u003e The physical trace routing handles high-frequency digital pulses and sensitive 4-20mA analog signals with equal accuracy. This flexibility allows engineers to standardize on a single FTA model across diverse marshalling zones, simplifying corporate spare parts inventory tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact, High-Density Structural Design:\u003c\/strong\u003e Measuring just 100 x 80 x 20 mm, the board snaps directly onto standard 35 mm DIN rails inside space-constrained control panels. The durable layout withstands heavy industrial vibrations and thermal cycling across an operational window of -20 to +60 degrees Celsius.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs the HIMA X-FTA00201 termination assembly a brand new factory unit or surplus stock?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eWe supply the X-FTA00201 board strictly as a 100% brand new, original, authentic factory unit. It arrives inside its original unopened manufacturer boxing with all protective seals intact, guaranteeing zero field usage hours and immaculate circuit trace performance.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this single termination board manage both analog input and digital output loops?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes. The X-FTA00201 acts as a transparent, isolated physical gateway. The type of signal it passes depends entirely on the specific HIMax I\/O module you connect to the board via the system interface ribbon cable. It handles analog variables and discrete digital switching states cleanly.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan I mount this termination board horizontally on standard cabinet DIN rails?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes. The rugged integrated base clips accommodate both vertical and horizontal 35 mm DIN rail configurations. This flexibility allows layout designers to position the termination block at the optimal angle to match incoming field-cable conduit pathways.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow does this assembly board improve long-term system troubleshooting inside petrochemical facilities?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eBy separating the field connections from the I\/O processing cards, the board creates a clear physical testing point. Field technicians can isolate individual signal loops or measure voltage drops directly at the X-FTA00201 screw terminals without risking damage to the main safety PLC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43865607340131,"sku":"X-FTA00201","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/148_528b6a81-cea7-4c32-bb7a-3570248c1fa1.jpg?v=1764569135","url":"https:\/\/www.autocontrolglobal.com\/products\/x-fta00201-hima-process-safety-field-termination-module","provider":"AutoControl Global","version":"1.0","type":"link"}