{"product_id":"x-sb01-hima-himax-system-bus-board-985210207-safety-modules","title":"X-SB01 HIMA HIMax System Bus Board 985210207 Safety Modules","description":"\u003ch2\u003eHIMA X-SB01 HIMax System Bus Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA X-SB01 985210207\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eX-SB01\u003c\/strong\u003e System Bus Board, operates as a dedicated hardware component for high-integrity backplane bus communication and regulated power routing within HIMax Safety Instrumented System (SIS) racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eX-SB01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e985210207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eHIMax \/ HIQuadX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety System Bus Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 x 165 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eDIN-rail \/ Panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Instrumented Systems \u0026amp; TMR Performance\u003c\/h3\u003e\n\u003cp\u003eDesigned for mission-critical automation environments, the X-SB01 implements full galvanic isolation across internal channels to mitigate common-cause electrical fault propagation. Compliant with IEC 61508 requirements up to SIL 3, the module supports triple modular redundancy (TMR) architectures, maintaining deterministic state execution and system availability. Built-in monitoring circuits continuously verify internal power distribution levels and trigger rapid fail-safe state execution in the event of an unrecoverable backplane voltage drop or communication signal degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the X-SB01 system bus board permit live insertion or hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the X-SB01 supports hot-swapping under live power, allowing system maintenance and module replacement without interrupting the safety controller's execution loop or compromising process safety integrity.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle fault containment across adjacent I\/O slots?\u003c\/p\u003e\n\u003cp\u003eA: Integrated galvanic isolation barriers and dedicated current-limiting pathways on the bus structure prevent localized electrical faults or overvoltage conditions on individual channels from propagating to adjacent controller or I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDuring installation, secure the X-SB01 to a standardized 35 mm DIN-rail or rigid backpanel using appropriate mechanical fasteners to ensure vibration resistance. Establish a direct, low-impedance ground connection from the system enclosure ground lug to the primary earth terminal using a heavy-gauge copper grounding strap. Route all 24 VDC auxiliary power feed lines through dedicated trunking, maintaining physical separation from high-voltage motor circuits and field switching lines to minimize inductive electromagnetic coupling. When terminating wires at the screw terminals, tighten all connections according to standard torque requirements and verify that shielded cable braids terminate to a single-point earth ground to eliminate potential ground loop currents.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43876664639587,"sku":"985210207","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/151_90aea590-b125-4130-8113-099e9bff9109.jpg?v=1765156379","url":"https:\/\/www.autocontrolglobal.com\/products\/x-sb01-hima-himax-system-bus-board-985210207-safety-modules","provider":"AutoControl Global","version":"1.0","type":"link"}