{"product_id":"yokogawa-aav141-s00-s2-analog-voltage-input-module","title":"Yokogawa AAV141-S00-S2 Analog Voltage Input Module","description":"\u003ch2\u003eYokogawa AAV141-S00-S2 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAAV141-S00-S2\u003c\/strong\u003e is a 16-channel analog voltage input module engineered for Yokogawa CENTUM VP and compatible Field Control I\/O (FIO) systems. It receives standardized 1 to 5 VDC analog voltage signals from field transmitters and instruments, converting process variables into digital data for system execution.\u003c\/p\u003e\n\u003ch3\u003eSignal Conversion \u0026amp; Input Circuitry\u003c\/h3\u003e\n\u003cp\u003eThe module features non-isolated differential inputs across 16 channels, maintaining high input resistance of at least 1 Mohm during energized operation and 340 kohm when powered off. With a data update period of 10 ms and a step response time of 100 ms, it processes analog inputs with an accuracy of +\/-4 mV.\u003c\/p\u003e\n\u003ch3\u003eConfiguration \u0026amp; Redundancy\u003c\/h3\u003e\n\u003cp\u003eThe -S00 suffix designates the standard module type without embedded specialized features, while the -S2 suffix specifies the standard option rating (basic specification without conformal coating or withstand voltage options). Dual-redundant module pairs are supported within compatible FIO node configuration bases to ensure high system availability.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAV141-S00-S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ FIO System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e1 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eNon-isolated differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-4 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-4 mV per 10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Common-Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-1 V or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e350 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What field signal type does the Yokogawa AAV141-S00-S2 accept? A: The module is designed specifically for 1 to 5 VDC analog voltage input signals across all 16 channels.\u003c\/p\u003e\n\u003cp\u003eQ: What does the -S2 suffix signify in the model number AAV141-S00-S2? A: The -S2 option suffix indicates a standard specification module variant within Yokogawa FIO ordering nomenclature.\u003c\/p\u003e\n\u003cp\u003eQ: Can the AAV141-S00-S2 be deployed in redundant configurations? A: Yes, two modules can be configured as a dual-redundant pair when installed in compatible CENTUM VP FIO redundant chassis slots.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67757003047011,"sku":"AAV141-S00","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/934.jpg?v=1792547082","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-aav141-s00-s2-analog-voltage-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}