{"product_id":"yokogawa-adv142-centum-cs-vp-digital-input-modules","title":"Yokogawa ADV142 CENTUM CS\/VP Digital Input Modules","description":"\u003ch2\u003eYokogawa ADV142 Digital Input Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV142-S02 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV142\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for processing high-voltage field signals within Yokogawa CENTUM CS and CENTUM VP distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV142 (Variant: ADV142-S02 S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107.5 mm x 130 mm x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 to 240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e160 V AC (226 V peak) to 264 V AC (373 V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 40 V AC (56 V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Input Current\u003c\/td\u003e\n\u003ctd\u003e6.2 mA per channel at 240 V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon every 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (signal to system), 1.35 kV AC between commons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eYokogawa CENTUM CS and CENTUM VP architecture integrates channel-to-channel isolation and robust input-filtering circuits directly within the module baseplate to prevent ground loops across field instrumentation networks. The module executes signal conditioning for high-voltage AC digital status inputs, routing galvanic isolation paths through internal optical couplers. These optical isolators withstand transient surge voltages up to 2 kV AC for 1 minute between field-side field wiring and backplane control logic. Furthermore, isolated groups organized into 8-channel commons prevent localized electrical faults or field neutral shifts from spreading across adjacent system processing channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support dual-redundant hardware configurations on the backplane?\u003c\/p\u003e\n\u003cp\u003eA: Yes, two ADV142 modules can sit in adjacent slots on a dual-redundant nested baseplate to maintain continuous digital status monitoring without interruption if one module suffers hardware failure.\u003c\/p\u003e\n\u003cp\u003eQ: What cable interfaces connect field wiring to the module?\u003c\/p\u003e\n\u003cp\u003eA: Field connections route via pressure-clamp terminals on dedicated terminal blocks or through specialized AKB333 cables mating directly to AEC4D terminal boards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure power is removed from field circuits before wiring to prevent electrical shock from 200-240 V AC lines. Route field cabling away from high-current motor leads to prevent capacitive coupling and noise induction into input channels.\u003c\/p\u003e\n\u003cp\u003eWhen terminating connections, secure individual conductors into pressure-clamp terminals, maintaining appropriate creepage and clearance distances across common groupings. Connect field signal shields to a single grounding point at the system cabinet ground bus to suppress ground potential interference.\u003c\/p\u003e\n\u003cp\u003eVerify that backplane latching mechanisms fully seat when locking the module into the subrack slot to ensure continuous power delivery and solid contact across backplane signal lines.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67584150863971,"sku":"ADV142","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/906.1.jpg?v=1790557469","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-adv142-centum-cs-vp-digital-input-modules","provider":"AutoControl Global","version":"1.0","type":"link"}