{"product_id":"yokogawa-adv151-p10-b5s10-centum-digital-input-module","title":"YOKOGAWA ADV151-P10\/B5S10 CENTUM Digital Input Module","description":"\u003ch2\u003eYOKOGAWA ADV151-P10\/B5S10 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in CENTUM VP, CS 3000, and CS 1000 system architectures, the \u003cstrong\u003eYOKOGAWA ADV151-P10\/B5S10\u003c\/strong\u003e (\u003cstrong\u003eADV151-P10\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution to monitor ON\/OFF field states across process plant control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P10\/B5S10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg (0.65 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81 x 103 x 146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e290 mA max (at 5 VDC), 140 mA max (at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eNo-voltage dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Condition\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 1 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF State Condition\u003c\/td\u003e\n\u003ctd\u003eGreater than or equal to 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e6 mA +\/- 20 percent (at 24 VDC, 0 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC between input signal and system logic (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal block with surge absorber (\/B5S10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Capability\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eField instruments tied to the 32-channel digital input board route through integrated galvanic isolation barriers designed to block high common-mode voltage spikes and suppress cross-talk across adjacent signal paths. With a withstand rating of 2 kV AC between input circuits and internal system logic, the module preserves signal integrity in heavy industrial noise environments. While CJC applies to analog temperature loops, this discrete module leverages channel-grouped noise filtering and internal 24 VDC loop conditioning to prevent spurious switching and ground loop currents.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing the module while the system is powered down disrupt adjacent I\/O cards on the rack?\u003c\/p\u003e\n\u003cp\u003eA: No. The card supports full online hot-swapping under live rack backplane power without interrupting communications or signal acquisition on neighboring modules.\u003c\/p\u003e\n\u003cp\u003eQ: How does the \/B5S10 option modify the physical connection interface compared to the standard module?\u003c\/p\u003e\n\u003cp\u003eA: The \/B5S10 option equips the unit with a pressure clamp terminal block that includes integrated surge absorbers to clamp line voltage transients before they reach internal optocoupler circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module directly into a designated slot on the CENTUM system node interface unit (NIU) or remote I\/O baseplate. Ensure that the locking mechanism fully engages with the backplane connector. Field wiring must route through shielded, twisted-pair cables, and the shield drain wire should terminate at a dedicated system ground bar using a short, low-impedance connection. Maintain a minimum of 5 full thread engagements when securing external terminal screw assemblies, and maintain physical segregation between field signal wiring and high-voltage AC power lines to prevent electromagnetic coupling.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":46226725175395,"sku":"ADV151-P10\/B5S10","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/886_e327537d-4918-4ffd-931b-040e1fd17f98.jpg?v=1790061464","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-adv151-p10-b5s10-centum-digital-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}