{"product_id":"yokogawa-adv151-p10-s2-centum-cs-digital-input-module","title":"YOKOGAWA ADV151-P10 S2 CENTUM CS Digital Input Module","description":"\u003ch2\u003eYOKOGAWA ADV151-P10 S2 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA ADV151-P10 S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete signal acquisition within CENTUM CS, CENTUM VP, CS 3000, and CS 1000 automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (9.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81 x 103 x 146 mm (1.0 x 5.0 x 5.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e290 mA max (at 5 VDC), 140 mA max (at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Count\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/- 20 percent per channel (6 mA +\/- 20 percent at 0 Ohm input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Permissible Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Withstand\u003c\/td\u003e\n\u003ctd\u003e2 kV AC between input signal and system logic (1 min), 500 V AC between commons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eStatus input: 8 ms or less; Pushbutton input: 20 ms (general response: \u0026lt;= 40 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal block or MIL connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Capability\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eDiscrete field contacts enter the module through high-density galvanic isolation networks designed to isolate internal bus logic from field transients up to 2 kV AC. Optical isolation barriers suppress ground loops and eliminate channel-to-channel cross-talk, preserving high-frequency signal integrity. Although cold junction compensation (CJC) applies directly to analog temperature sensing circuits, the discrete signal conditioning pipeline inside this module uses RC noise filtering and voltage thresholds to eliminate contact bounce and electromagnetic interference across high-density I\/O racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does removing the module from a live rack disrupt bus communication on adjacent I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: No. The card supports hot-swapping under live backplane power, allowing online replacement without interrupting power distribution or bus communications on neighboring slots.\u003c\/p\u003e\n\u003cp\u003eQ: What input conditions are required for the module to register a logical ON state?\u003c\/p\u003e\n\u003cp\u003eA: The channel detects an ON state when the field input voltage ranges between 18 and 26.4 VDC or when dry-contact loop resistance drops below 1 kOhm.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module into an open I\/O slot on the CENTUM system baseplate, pressing firmly until the retaining latches secure it into the backplane. Route all 24 VDC discrete signal wiring through shielded twisted-pair cables and connect the shield drain wire to a single-point earth ground bar. Maintain physical segregation between signal lines and power cabling to mitigate capacitive noise, and verify that all pressure clamp terminal connections remain tightened to avoid intermittent contact loss.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":46226775441507,"sku":"ADV151-P10 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/895..jpg?v=1790062689","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-adv151-p10-s2-centum-cs-digital-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}