{"product_id":"yokogawa-adv159-p01-s1-centum-vp-digital-input-module","title":"Yokogawa ADV159-P01 S1 CENTUM VP Digital Input Module","description":"\u003ch2\u003eYokogawa ADV159-P01 Digital Input Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV159-P01 S1\u003c\/strong\u003e serves as the primary \u003cstrong\u003eADV159\u003c\/strong\u003e Digital Input Module utilized to execute digital field signal acquisition across Yokogawa CENTUM VP, CENTUM CS, and ProSafe-RS platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV159\u003c\/td\u003e\n\u003ctd\u003e-P01\u003c\/td\u003e\n\u003ctd\u003eStandard digital input module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eS1\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 conformal coating option for environmental protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV159-P01 S1 (Base Model: ADV159)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa CENTUM VP subrack module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels (S1 configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e11 to 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Input Current\u003c\/td\u003e\n\u003ctd\u003e4.7 mA per channel at 120 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system optical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (signal to system); 1.35 kV AC between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eYokogawa CENTUM VP and ProSafe-RS architectures employ comprehensive optical isolation stages to insulate high-density digital input channels from field noise and voltage spikes. The individual channel isolation scheme isolates incoming DC control loops across a wide 24 to 250 VDC potential band. This galvanic isolation prevents common-mode noise transfer into core processing logic and maintains signal integrity across distributed field instrumentation without cross-channel coupling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the S1 suffix alter the module environmental specification?\u003c\/p\u003e\n\u003cp\u003eA: The S1 suffix designates compliance with ISA Standard G3 conformal coating guidelines, providing physical protection against corrosive gas atmospheres.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module operate within a dual-redundant I\/O subrack slot pair?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports dual-redundant subrack configurations to maintain continuous signal processing if one card experiences hardware interruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure main subrack power and field loop supplies are disconnected prior to inserting or removing the module from the baseplate slot.\u003c\/p\u003e\n\u003cp\u003eWhen landing field wiring on terminal panels, maintain separate cable trays for high-voltage DC field inputs and low-level analog or communication cables to minimize cross-talk. Ground all cable shields at a single dedicated system earth busbar within the cabinet.\u003c\/p\u003e\n\u003cp\u003eVerify that the module subrack locking mechanism fully engages during mounting to maintain positive electrical contact along the system backplane bus.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67584422838371,"sku":"ADV159-P01 S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/909.jpg?v=1790558631","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-adv159-p01-s1-centum-vp-digital-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}