{"product_id":"yokogawa-adv161-p00-s2-centum-vp-digital-input-modules","title":"Yokogawa ADV161-P00 S2 CENTUM VP Digital Input Modules","description":"\u003ch2\u003eYokogawa ADV161-P00 S2 Digital Input Modules\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density 24 VDC status signal acquisition in Yokogawa CENTUM VP and FIO systems, the \u003cstrong\u003eYokogawa ADV161-P00 S2\u003c\/strong\u003e (\u003cstrong\u003eADV161\u003c\/strong\u003e Digital Input Module) provides direct physical signal processing from field switches, relays, and pushbutton circuits.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV161\u003c\/td\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pulse width input \/ pushbutton input functionality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eS2\u003c\/td\u003e\n\u003ctd\u003eEnhanced style version for updated component release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV161-P00 S2 (Base Model: ADV161)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 mm x 107 mm x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e550 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Maximum allowable: 30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSink \/ Source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e20 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2.5 mA +\/- 20% per channel at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Scheme\u003c\/td\u003e\n\u003ctd\u003eCommon every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (signal to system); 500 V AC for 1 minute (between commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface\u003c\/td\u003e\n\u003ctd\u003eDedicated AKB337 cable or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eYokogawa CENTUM VP distributed control architectures implement high-density optocoupler isolation arrays to separate 24 VDC field input loops from sensitive backplane logic. The 64 input channels organize into discrete 16-channel groups sharing individual common rails, mitigating ground differential interference across long-distance wiring runs. Internal signal conditioning circuitry accommodates sink or source input topologies, providing galvanic isolation up to 2 kV AC for 1 minute between signal lines and internal system buses.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What external terminal boards connect to the module for 64-channel field termination?\u003c\/p\u003e\n\u003cp\u003eA: Field connections route via dedicated AKB337 cables or MIL connector assemblies to external terminal boards such as the AED5D or A1BD5D, requiring two terminal boards to break out all 64 channels.\u003c\/p\u003e\n\u003cp\u003eQ: What response performance does the input circuit deliver for pushbutton and status monitoring?\u003c\/p\u003e\n\u003cp\u003eA: The input stage processes status inputs with a response time of \u0026lt;= 8 ms and handles pushbutton pulse edges at a maximum frequency of 25 Hz with a minimum ON detection window of 20 ms.\u003c\/p\u003e\n\u003cp\u003eQ: Is dual-redundant hardware installation supported on the I\/O baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Yes, two ADV161-P00 S2 modules can sit in adjacent subrack slots to maintain continuous digital input processing under dual-redundant control mode.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure system backplane power and 24 VDC field loop power are completely disconnected prior to inserting or removing the module from the subrack.\u003c\/p\u003e\n\u003cp\u003eWhen routing 64-point field wiring harnesses, maintain separate wireways for DC discrete inputs away from high-voltage AC lines to prevent capacitive noise coupling. Ground cable shields at a single dedicated earth busbar inside the DCS cabinet.\u003c\/p\u003e\n\u003cp\u003eSecure connector locking screws on the AKB337 cable assemblies to maintain low-impedance grounding across shield connections. Seat the module firmly into the baseplate until side retention latches click fully into place.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67584508428387,"sku":"ADV161-P00 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/911..jpg?v=1790559243","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-adv161-p00-s2-centum-vp-digital-input-modules","provider":"AutoControl Global","version":"1.0","type":"link"}