{"product_id":"yokogawa-adv551-p03-s2-centum-fio-digital-output-module","title":"Yokogawa ADV551-P03 S2 CENTUM FIO Digital Output Module","description":"\u003ch2\u003eYokogawa ADV551-P03 S2 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed signal actuation and field device driving in Yokogawa CENTUM VP and FIO architectures, the \u003cstrong\u003eYokogawa ADV551-P03 S2\u003c\/strong\u003e (\u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. This 32-channel isolated module processes current-sink transistor outputs to manage field elements such as solenoids, relays, and indicators without sacrificing system bus integrity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P03 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 mm x 107 mm x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA at 5 VDC (system); 60 mA (external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor contact (Current-sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\/channel at 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=3 ms (Status output); \u0026lt;=10 ms (Pulse output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC output-to-system; 500 V AC common-to-common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Arrangement\u003c\/td\u003e\n\u003ctd\u003eMinus-side common every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eField Network I\/O and Advanced Pulse Output Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe ADV551-P03 S2 integrates directly with Yokogawa FIO control system backplanes. Beyond standard ON\/OFF switching, the module supports hardware-level pulse-width outputs and time-proportional control. Each channel features a selectable one-shot pulse range from 8 ms to 7200 s with an 8 ms resolution. High-density channel-to-channel isolation safeguards the primary control bus against field-side electrical surges and ground loops, maintaining signal integrity under heavy industrial load switching.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the ADV551-P03 S2 respond when configured in a dual-redundant FIO slot pair?\u003c\/p\u003e\n\u003cp\u003eA: When you configure two ADV551-P03 S2 modules in a dual-redundant slot pair, the system actively monitors channel integrity. If the active module experiences a system-side bus failure or power drop, the secondary module takes over signal driving within microseconds without dropping output states or resetting active pulse timers.\u003c\/p\u003e\n\u003cp\u003eQ: What are the wiring constraints for the 16-channel minus-side common structure?\u003c\/p\u003e\n\u003cp\u003eA: You must supply external 24 VDC power directly to both minus-side common banks. Ensure that the total current draw per 16-channel group does not exceed the backplane power supply limit, and connect field loads between the positive rail and the module sink terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the ADV551-P03 S2 firmly into the target FIO node slot until the locking levers engage. Before powering up the rack, connect dedicated AKB331 cables or pressure clamp terminal blocks to the front interface connector. Route all 24 VDC digital output wiring through separate cable channels, keeping them well away from high-voltage AC distribution lines to eliminate inductively coupled noise. Ground the overall cable shield at a single low-impedance cabinet earth terminal to comply with galvanic isolation and EMI suppression requirements.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50524042821731,"sku":"ADV551-P03 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/897.1_84d4fa65-e850-4875-8461-7fbb02888210.jpg?v=1790238470","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-adv551-p03-s2-centum-fio-digital-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}