{"product_id":"yokogawa-adv559-p01-centum-vp-digital-output-module","title":"Yokogawa ADV559-P01 CENTUM VP Digital Output Module","description":"\u003ch2\u003eYokogawa ADV559-P01 Digital Output Modules\u003c\/h2\u003e\n\u003cp\u003eConfigured for precision discrete control and pulse timing execution in Yokogawa CENTUM VP and ST4-compatible systems, the \u003cstrong\u003eYokogawa ADV559-P01\u003c\/strong\u003e (\u003cstrong\u003eADV559\u003c\/strong\u003e Digital Output Module) provides direct physical current-sink switching for field-side actuators.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV559\u003c\/td\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pulse-width and time-proportioning output functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eISA G3 conformal coating for harsh environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV559-P01 (Base Model: ADV559)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.8 mm x 127.2 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e570 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eTransistor contact, sink type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel maximum (resistive or inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s (8 ms resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eElectrically isolated output signal channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Method\u003c\/td\u003e\n\u003ctd\u003eDedicated KS2 interface cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eYokogawa CENTUM VP process control architectures utilize high-density optical isolation barriers to separate internal system logic from 30 VDC field loop potentials. The module routes 32 discrete sink-type transistor channels through galvanic isolation circuitry, mitigating earth loop currents and preventing transient voltage feedback across high-density field lines. Integrated pulse generation networks support time-proportioning and pulse-width duty cycles down to an 8 ms timing resolution, while the conformal coating complies with ISA G3 environmental specs to resist airborne corrosive pollutants.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What interconnect hardware is required to wire field loads to the module?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes dedicated Yokogawa KS2 interface cables to connect field output signals directly to external termination boards.\u003c\/p\u003e\n\u003cp\u003eQ: Does the -P01 suffix version support special timing output modes?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the -P option enables built-in pulse-width output and time-proportioning output modes with a programmable pulse range from 8 ms to 7200 seconds.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive loads such as solenoid coils?\u003c\/p\u003e\n\u003cp\u003eA: The open-collector output transistors handle up to 100 mA per channel at 30 VDC for both resistive and inductive loads; external flywheel diodes are recommended at the load terminals for high-inductance circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify that system rack power and external 30 VDC field power supplies are completely turned off prior to installing or removing the module from the subrack slot.\u003c\/p\u003e\n\u003cp\u003eRoute external KS2 cables through dedicated cable ducting, maintaining physical separation between low-voltage discrete signal lines and high-voltage AC power wiring to prevent electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure cabinet ground bars connect firmly to system ground and verify that the module retention mechanisms click securely into the mounting rack to guarantee conformal-coated interface contacts mate fully with backplane power buses.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67584697270371,"sku":"ADV559","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/913..jpg?v=1790559832","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-adv559-p01-centum-vp-digital-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}