{"product_id":"yokogawa-ata4s-s00-s2-pressure-clamp-dcs-terminal","title":"Yokogawa ATA4S-S00 S2 Pressure Clamp DCS Terminal","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ATA4S-S00 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density interface for signal acquisition within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems. This 16-channel module captures precise 4–20 mA DC current loops from field transmitters, sensors, and flowmeters. By utilizing a pressure clamp terminal architecture, the ATA4S-S00 S2 ensures secure, gas-tight connections that withstand industrial vibrations. It provides the essential data link required for real-time process monitoring, safety interlocking, and industrial data logging.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ATA4S\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eATA4S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Channel Analog Input Module (Pressure Clamp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersion suffix indicating specific hardware revision\/certification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ATA4S-S00 S2 meets rigorous industrial benchmarks for accuracy and environmental resilience:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 independent channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4–20 mA DC (Typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure clamp terminal block (Tool-free wiring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA G3 Standard (Corrosion resistance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull channel-to-channel and channel-to-ground isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP54 equivalent (When correctly installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRack-mounted in DCS I\/O subsystems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New in original factory packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eISA G3 Corrosion Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ATA4S-S00 S2 complies with the ISA G3 standard, protecting internal circuitry against harsh atmospheric contaminants like Hydrogen Sulfide (\u003cspan class=\"math-inline\"\u003e$H_2S$\u003c\/span\u003e) and Chlorine (\u003cspan class=\"math-inline\"\u003e$Cl_2$\u003c\/span\u003e). This makes it indispensable for wastewater treatment, paper mills, and petrochemical facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Proof Pressure Clamps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe tool-free pressure clamp mechanism eliminates the risk of loose screw terminals. This design maintains constant contact pressure even in high-vibration environments near turbines or heavy pumps, preventing intermittent signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Rack Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePacking 16 channels into a compact rack-mount footprint allows engineers to minimize the number of I\/O sub-nests required. This reduces total cabinet space and lowers the overall cost of the control system infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSophisticated isolation barriers shield the system backplane from field-side electrical surges and ground loops. This ensures that a single-channel failure does not propagate to the CPU or disrupt the remaining 15 inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the ATA4S-S00 S2 handle 0–10V voltage signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The ATA4S-S00 S2 is specifically engineered for 4–20 mA current loops. If your application requires voltage inputs, you must utilize a precision shunt resistor or select a different Yokogawa module model such as the AAV series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What are the installation requirements for ISA G3 compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo fully leverage the ISA G3 rating, you must install the module within a properly sealed DCS cabinet. The module's conformal coating protects the PCB, but ensuring clean filtered air within the enclosure further extends the lifespan of the entire system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module support 2-wire transmitter powering?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ATA4S-S00 S2 primarily acts as the terminal interface. Powering for 2-wire transmitters depends on the specific AAI input module paired with this terminal block. Ensure your system configuration supports the loop power requirements of your field instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I verify the authenticity of the \"S2\" version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery unit we supply is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. The \"S2\" revision is verified via the factory serial number and the holographic seals on the Yokogawa original packaging. We provide full traceability for all DCS components.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43802072318051,"sku":"ATA4S-S00 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/35_98230452-0330-427c-bf9c-1afce41c796f.jpg?v=1761808525","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-ata4s-s00-s2-pressure-clamp-dcs-terminal","provider":"AutoControl Global","version":"1.0","type":"link"}