{"product_id":"yokogawa-nfcp501-s05-s2-stardom-fcn-500-cpu-module","title":"Yokogawa NFCP501-S05 S2 STARDOM FCN-500 CPU Module","description":"\u003ch2\u003eYokogawa NFCP501-S05 S2 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP501-S05 S2\u003c\/strong\u003e (\u003cstrong\u003eNFCP501-S05 S2\u003c\/strong\u003e CPU Module) serves as the primary control unit utilized to execute real-time logic and network communication across STARDOM FCN-500 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP501-S05 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 28 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to system backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC, 400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB (ECC-protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e64 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Integration and Process Control\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNFCP501-S05 S2\u003c\/strong\u003e enables deterministic communication via the Vnet\/IP protocol, providing a bridge between local control logic and larger CENTUM VP or ProSafe-RS infrastructures. The module architecture ensures channel-to-channel isolation on the I\/O expansion bus to prevent signal degradation. Furthermore, the unit supports 4-20 mA HART loop protocol connectivity, allowing for the transmission of asset management data and diagnostic parameters from field-level instrumentation directly to the controller memory.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFCP501-S05 S2 support hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping. When configured in a redundant pair, the standby unit maintains the process control state, allowing for the extraction and replacement of the faulty module without system interruption.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module maintain memory integrity during logic execution?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes ECC-protected memory for both program and data storage, which automatically detects and corrects single-bit errors to ensure logic stability and prevent unexpected controller faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion\u003c\/strong\u003e: Align the module with the chassis guide rails. Ensure the connectors are fully seated before engaging the locking levers to maintain stable communication with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Controls\u003c\/strong\u003e: Ensure the installation cabinet provides adequate ventilation. Although the module operates up to 60 deg C, maintaining an ambient temperature below 40 deg C prolongs the service life of internal electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Use high-quality shielded twisted-pair cabling for all network and I\/O connections. Terminate the shield at the cabinet ground bar to mitigate the effects of electromagnetic interference (EMI) on the communication ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Wiring\u003c\/strong\u003e: When installing in a redundant pair, verify that both CPUs are linked via the dedicated sync cable. Ensure power supplies are derived from independent, fault-tolerant sources to prevent a single power failure from disabling the redundant control set.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43856089808995,"sku":"NFCP501-S05 S1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/167.1_91e816e3-762e-47c0-b872-5494a78beee4.jpg?v=1764125867","url":"https:\/\/www.autocontrolglobal.com\/products\/yokogawa-nfcp501-s05-s2-stardom-fcn-500-cpu-module","provider":"AutoControl Global","version":"1.0","type":"link"}