{"product_id":"8-channel-analog-output-module-8104-ao-ip-ge-fanuc","title":"8-Channel Analog Output Module 8104-AO-IP | GE Fanuc","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc 8104-AO-IP 8-Channel Analog Output Module – Product Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Summary\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc 8104-AO-IP is an 8-channel analog output module from the PAC8000 series, designed for precise current-loop signal control in industrial automation. Each channel delivers 4–20 mA output, with 12-bit resolution and built-in open circuit detection. Moreover, the module supports fail-safe operation and configurable initialization states, ensuring reliable performance even in critical process applications. Its compact, carrier-mounted design allows flexible DIN-rail or flat-surface mounting, making it suitable for both new installations and upgrades. The rugged industrial build supports operation in hazardous areas, offering dependable service in demanding environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturer: GE \/ MTL (PAC8000 series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: 8104-AO-IP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: 8-Channel Analog Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: .5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact carrier-mounted design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail or flat-surface mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 single-ended analog output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal signal range: 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull signal range: 1–23 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 12-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.25% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance \u0026amp; Response\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eResponse time: ≤25 ms (Railbus command to output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel status reporting (active\/inactive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable initialization state (predefined value)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrive on fail-safe: predefined or last value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics \u0026amp; Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOpen-circuit detection per channel (0.7 ±0.25 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel to Railbus isolation: 100 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFM non-incendive parameters: 28.7 V, 33 mA, 0.17 μF, 11.0 mH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField power: 24 VDC bussed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput compliance: 20 mA at 21.6 VDC (into 700 Ω load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: –40 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged industrial design for hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. How many output channels does the 8104-AO-IP support?\u003c\/strong\u003e\u003cbr\u003eIt provides eight single-ended analog output channels for process control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is the nominal signal range of each output?\u003c\/strong\u003e\u003cbr\u003eEach channel operates in the 4–20 mA range, with a full range of 1–23 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Does the module include diagnostic features?\u003c\/strong\u003e\u003cbr\u003eYes, it offers per-channel open-circuit detection and channel status reporting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What field power is required for operation?\u003c\/strong\u003e\u003cbr\u003eThe module requires 24 VDC bussed field power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Can the module operate in hazardous environments?\u003c\/strong\u003e\u003cbr\u003eYes, it has a rugged design suitable for industrial hazardous areas.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872778256483,"sku":"8104-AO-IP","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/410._56308ddb-f835-48d9-b9e5-1c59f4a7b6e5.jpg?v=1764917858","url":"https:\/\/www.autocontrolglobal.com\/ru\/products\/8-channel-analog-output-module-8104-ao-ip-ge-fanuc","provider":"AutoControl Global","version":"1.0","type":"link"}