KJ1501X1-BC2 by Emerson – SIS CHARMs Baseplate
KJ1501X1-BC2 by Emerson – SIS CHARMs Baseplate
KJ1501X1-BC2 by Emerson – SIS CHARMs Baseplate
/ 3

KJ1501X1-BC2 by Emerson – SIS CHARMs Baseplate

  • Manufacturer: GE Fanuc

  • Part Number: KJ1501X1-BC2 12P2186X042

  • Condition:New with Original Package

  • Product Type: SIS CHARMs Baseplate

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson KJ1501X1-BC2 Product Description

Overview

The Emerson KJ1501X1-BC2 (12P2186X042) is a reliable CSLS baseplate designed for DeltaV Safety Instrumented System installations. It provides a secure mechanical structure that supports Smart Logic Solver modules and their associated CHARMs. Moreover, the baseplate delivers stable power distribution and clean communication pathways that help safety teams maintain uninterrupted SIS performance. Its rugged construction withstands demanding plant environments, therefore supporting facilities operating with strict uptime and safety requirements.

Technical Specifications

Model: KJ1501X1-BC2
Part Number: 12P2186X042
Assembly Code: VE5008
Type: CSLS Baseplate / Carrier
System Compatibility: Emerson DeltaV SIS (CHARMs subsystem)
Supported Modules: CSLS Smart Logic Solver + CHARMs
Power Distribution: 24 VDC bussed field power
LocalBus Rating: 12 VDC at 150 mA
Bussed Field Rating: 12 VDC at 300 mA
Field Circuit Rating: 24 VDC at 32 mA
Dimensions (H × W × D): 107 × 41 × 105 mm
Weight: 0.25 kg
Operating Temperature: –40°C to +70°C
Storage Temperature: –40°C to +85°C
Humidity Range: 5%–95% non-condensing
Shock Resistance: 10 g half-sine, 11 ms
Vibration Resistance: 1 mm p-p (2–13.2 Hz), 0.7 g (13.2–150 Hz)
Airborne Contaminants: ISA-S71.04 Class G3
Protection Class: IP20
Certifications: CE, UL, ATEX, IECEx, FM, UKEX (Zone 2 / Class I Div.2)
Product Origin: USA
Shipping Port: Xiamen, China
Payment: T/T
Lead Time: In stock

FAQ

Q1: What is the primary function of the KJ1501X1-BC2 baseplate?
It provides mechanical mounting and electrical connectivity for CSLS modules and CHARMs within DeltaV SIS.

Q2: Is it certified for hazardous environments?
Yes, it meets ATEX, IECEx, FM, UL, and UKEX Zone 2 / Class I Div.2 requirements.

Q3: Which DeltaV components does it support?
It supports Smart Logic Solver modules and all compatible CHARMs for flexible I/O configuration.

Q4: Can it be used in emergency shutdown systems?
Yes, it is widely used in ESD, fire and gas, and other high-integrity safety applications.

Q5: Does it include built-in power distribution?
Yes, it delivers stable 24 VDC bussed field power and LocalBus power for CSLS operation.