DeltaV SE3051C0 | Emerson S-Series Hardware Carrier
DeltaV SE3051C0 | Emerson S-Series Hardware Carrier
DeltaV SE3051C0 | Emerson S-Series Hardware Carrier
/ 3

DeltaV SE3051C0 | Emerson S-Series Hardware Carrier

  • Manufacturer: GE Fanuc

  • Part Number: SE3051C0

  • Condition:New with Original Package

  • Product Type: horizontal power/controller carrier

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson SE3051C0 Power/Controller Carrier

Product Description

The Emerson SE3051C0 is a horizontal two-wide carrier designed for the DeltaV S-series hardware platform. It mounts one controller and one power supply side by side, creating a compact architecture for distributed systems. Moreover, its integrated power distribution simplifies field wiring and reduces installation time, making the carrier suitable for both new automation builds and system expansions. The sturdy mechanical design withstands harsh industrial conditions while providing stable electrical connectivity for long-term operation.

Technical Specifications

Model: SE3051C0
Type: 2-wide horizontal power/controller carrier
System Compatibility: Emerson DeltaV S-series DCS
Capacity: Holds 2 modules (controller + power supply)

Electrical Ratings:

  • Backplane Current: 15 A

  • Power Terminal Plug: 12 A

  • Power Buss Plug (fused): 5 A

  • Primary/Secondary 24 VDC Bussed Power: 12 A per bus (Max 3 A per card)

Environmental Ratings:

  • Operating Temperature: –40 to +70 °C

  • Storage Temperature: –40 to +85 °C

  • Relative Humidity: 5% to 95%, non-condensing

  • Shock: 10 g, ½-sine wave for 11 ms

  • Vibration: 1 mm peak-to-peak (5–13.2 Hz), 0.7 g (13.2–150 Hz)

Mechanical Details:

  • IO Carrier Capacity: 8 I/O modules

  • Dimensions (H × W): 90 × 229 mm

  • Weight: 1 kg

Certifications: CE, UL, ATEX, IECEx
Country of Origin: USA
Part Number: SE3051C0

FAQ

1. What modules can the SE3051C0 support?
It supports one DeltaV controller and one DeltaV power supply mounted horizontally.

2. Does the carrier provide bussed power distribution?
Yes, it distributes primary and secondary 24 VDC bussed power to the connected modules.

3. What is the maximum backplane current rating?
The carrier supports up to 15 A of backplane current.

4. Is this carrier suitable for harsh environments?
Yes, it withstands wide temperature ranges, high shock, and mechanical vibration.

5. Can it be used in hazardous locations?
Yes, it is certified for CE, UL, ATEX, and IECEx, supporting Zone 2 / Class I Div. 2.