{"product_id":"ge-energy-is220pprfh1b-profibus-master-gateway-12mbps","title":"GE Energy IS220PPRFH1B PROFIBUS Master Gateway 12Mbps","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS220PPRFH1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance PROFIBUS Master Gateway within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe Speedtronic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol architecture. This module facilitates bi-directional, real-time data exchange between PROFIBUS DP slave devices and the Mark VIe I\/O Ethernet network. By utilizing an onboard 32-bit embedded processor and a dedicated Hilscher COM-C communication chip, the IS220PPRFH1B offloads complex protocol processing from the main controller, ensuring deterministic performance for critical turbine automation tasks in gas, steam, and wind power applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220PPRFH1B (Revision B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP V0 and DP V1 Master\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-485 via DE-9 Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 kbps to 12 Mbps (Auto-detection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 125 PROFIBUS Slave Devices\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Throughput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 Bytes Input \/ 244 Bytes Output per slave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Connectivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 100Base-TX RJ-45 Ports (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 VDC Nominal (27.4 to 28.6 VDC range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 Degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\/Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit Processor, 8MB Flash, 4MB DRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating on PCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL\/cUL Class I Div 2, ATEX Zone 2, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dedicated Hilscher COM-C chip manages the PROFIBUS cycle independently. This prevents high-traffic fieldbus noise from impacting the Mark VIe Ethernet backbone, maintaining system stability during network congestion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe -40 to +70 C operating range and conformal coating allow installation in remote wind turbine nacelles or unconditioned turbine enclosures. It withstands 50g shock loads, making it suitable for high-vibration industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual RJ-45 ports support the Mark VIe IONet architecture. If one Ethernet path fails, the module maintains communication without interrupting the turbine control loop, eliminating single points of failure at the gateway level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module maps PROFIBUS data directly into the ToolboxST configuration environment. Engineers manage field devices as standard I\/O points, reducing the time required for third-party device integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with older Mark VI systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS220PPRFH1B is specifically designed for the Mark VIe and Mark VIeS architectures using the IONet Ethernet protocol. It is not directly compatible with the older VME-bus based Mark VI systems without an interface bridge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support PROFIBUS DP V1 acyclic messaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports both DP V0 cyclic data and DP V1 acyclic communication, allowing for advanced device diagnostics and parameterization of smart field instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the power requirements during startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws a maximum current of 0.18A at a nominal 28V DC. Ensure your power supply maintains a steady voltage within the 27.4 to 28.6 VDC range to prevent communication resets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an 'H1A' revision with this 'H1B' module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the IS220PPRFH1B (Revision B) is backward compatible with the H1A version. It offers improved hardware stability while maintaining the same physical footprint and logical mapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44183814340707,"sku":"IS220PPRFH1B","price":580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/560._5c4186fd-a702-48b4-9c9d-dfd5e87d69d9.jpg?v=1778830547","url":"https:\/\/www.autocontrolglobal.com\/tr\/products\/ge-energy-is220pprfh1b-profibus-master-gateway-12mbps","provider":"AutoControl Global","version":"1.0","type":"link"}