EPRO CON011/914-100 Eddy-Current Signal Converter – Product Description
Overview
The Emerson EPRO CON011/914-100 is a hardened eddy-current signal converter engineered for demanding rotating-machinery environments. It delivers accurate, stable signal conditioning for proximity probes used in vibration monitoring and shaft-position measurement. Moreover, the converter integrates seamlessly with the PR6422–PR6426 probe families, allowing technicians to maintain consistent performance across mixed machine assets. The robust design supports API 670 compliant protection systems, and it performs reliably in high-temperature and high-noise environments common to turbine and compressor applications.
Technical Specifications
Electrical & Signal Performance
• Frequency Response (–3 dB): 0 to 20,000 Hz
• Rise Time: <15 μs
• Output Signal: Scaled voltage proportional to shaft movement
• Input Resistance: >100 kΩ (supports cable runs up to 300 m)
• Supply Voltage Range:
– –23 V to –32 V (Output –4 V to –20 V)
– –21 V to –32 V (Output –2 V to –18 V)
Compatibility
• Supported Sensors: PR6422, PR6423, PR6424, PR6425, PR6426
• Extended Range Support: CON011/91x-xxx variants required for PR6425
Mechanical Design
• Housing Material: GD-ALSi9Cu3 aluminum alloy
• Weight: 600 g
• Mounting: Hardened panel-mount design with 4 × M5×20 screws
• Connections: Screw terminals for probe input and signal output
Environmental Ratings
• Operating Temperature: –30 °C to +100 °C
• Vibration Resistance: 5 g @ 60 Hz @ 25 °C
• Protection Class: IP65
FAQ
Q1: Which probes work with the CON011/914-100?
The converter supports the full PR6422–PR6426 proximity probe range, including extended-range models.
Q2: Can it be used in high-temperature machinery areas?
Yes, it operates reliably from –30 °C to +100 °C, which suits turbine bearing housings and compressor enclosures.
Q3: Is the module compliant with API 670 requirements?
Yes, its performance specifications and signal stability support API 670 compliant protection architectures.
Q4: How is the unit typically mounted?
It uses a four-point hardened panel mount with M5×20 screws for stable mechanical installation.
Q5: Does long-distance cabling affect accuracy?
No, the high input resistance maintains signal integrity across cable runs up to roughly 300 meters.