KJ4002XI-BF2 | Emerson DeltaV Modular LocalBus Link Module
KJ4002XI-BF2 | Emerson DeltaV Modular LocalBus Link Module
KJ4002XI-BF2 | Emerson DeltaV Modular LocalBus Link Module
/ 3

KJ4002XI-BF2 | Emerson DeltaV Modular LocalBus Link Module

  • Manufacturer: GE Fanuc

  • Part Number: KJ4002XI-BF2

  • Condition:New with Original Package

  • Product Type: DeltaV Modular LocalBus Link Module

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Description

The KJ4002XI-BF2 is a LocalBus extender designed for Emerson’s DeltaV™ DCS architecture, providing seamless communication between multiple I/O carriers. It ensures high-speed data exchange while maintaining signal integrity across large-scale automation systems. Moreover, this module simplifies system expansion in modular DCS setups by allowing both vertical and horizontal carrier linking without compromising performance.

Its compact design and DIN rail or cabinet mounting make it suitable for space-constrained installations. In addition, the KJ4002XI-BF2 meets hazardous area certifications, ensuring safe operation in industrial environments such as chemical, oil and gas, and power plants.

 Technical Specifications

Attribute Specification
Model KJ4002XI-BF2
Type LocalBus Extender
Function Extends LocalBus communication between I/O carriers
Dimensions 185 × 125 × 45 mm
Weight 0.95 kg
Power Supply 12.6 VDC @ 15 A (LocalBus)
Hazardous Area Ratings II 3G Ex ec IIC Gc / Class I Div 2 Groups A–D
Certifications ATEX, FM, UKEX
Installation Note Must be de-energized before removal or insertion
Mounting DIN rail or cabinet-mounted
Country of Origin USA
Shipping Port Xiamen, China

Typical Applications

  • Linking multiple DeltaV I/O carriers in modular DCS installations.

  • Large-scale industrial automation in chemical, oil & gas, or power facilities.

  • Systems requiring high-speed LocalBus communication and signal integrity.

  • Environments where space optimization and flexible carrier arrangement are necessary.

FAQ

Q1: What is the primary function of the KJ4002XI-BF2?
A1: It extends LocalBus communication between multiple DeltaV I/O carriers.

Q2: Can it be mounted on a DIN rail?
A2: Yes, it supports both DIN rail and cabinet-mounted installations.

Q3: Is it certified for hazardous locations?
A3: Yes, it meets ATEX, FM, and UKEX hazardous area certifications.

Q4: What is the required power supply for this module?
A4: The LocalBus requires 12.6 VDC at 15 A for proper operation.

Q5: Should the module be energized during installation?
A5: No, it must be de-energized before removal or insertion for safety.