Bently Nevada 200200-02-02-CN Dual-Input Condition Monitoring Module
/ 1

Bently Nevada 200200-02-02-CN Dual-Input Condition Monitoring Module

  • Manufacturer: Bently Nevada

  • Part Number: 200200-02-02-CN

  • Condition:New with Original Package

  • Product Type: Dual-Input Condition Monitoring Module

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Bently Nevada 200200-02-02-CN – Dual-Input proTIM-R Module

Overview

The Bently Nevada 200200-02-02-CN is a dual-input proTIM-R module designed for distributed condition monitoring within the Trendmaster® Pro system. It provides two independent channels for vibration and temperature measurements, supporting accelerometers, velocity sensors, RTDs, and thermocouples.

Thanks to its DIN rail design, the module integrates easily into industrial panels. Its advanced signal conditioning functions, including acceleration-to-velocity (A-V) conversion and acceleration enveloping (AE), allow precise fault detection and early maintenance intervention. Electrical isolation for temperature inputs ensures reliable and interference-free measurements.

This module is widely used in industries such as oil and gas, power generation, and manufacturing for monitoring rotating machinery including pumps, compressors, and fans.

Technical Specifications

Feature Specification
Model Number 200200-02-02-CN
Manufacturer Bently Nevada 
Series 200 Series proTIM-R (Trendmaster® Pro)
Input Channels 2 independent, configurable
Sensor Compatibility Accelerometers, velocity sensors, RTDs, thermocouples
Signal Conditioning Acceleration-to-Velocity (A-V), Acceleration Enveloping (AE)
Frequency Response DC to 3 kHz
Voltage Measurement Range 0 to 50 mV
Resolution ±1% of full-scale (typical)
Accuracy ±8.5% of transducer rating (excluding sensor error)
Current Range +4 mA to +20 mA
Voltage Range +1 VDC to +5 VDC
Over Range Current <+3 mA or >+22 mA
Over Range Voltage <+0.8 VDC or >+5.5 VDC
OK Range (Current) >+3.2 mA
OK Range (Voltage) >0.8 VDC
Bias OK Range 1 VDC to 3 VDC from transducer
Electrical Isolation Yes, for temperature inputs
Power Supply 24 V DC
Communication RS-485, Trendmaster® Pro network
Mounting DIN rail

 